![Atag i15R Technical Manual Download Page 27](http://html.mh-extra.com/html/atag/i15r/i15r_technical-manual_2995190027.webp)
Parameter listing
Parameter
number
Name
Description
Unit
Range
Default
Combi
2. BOILER PARAMETERS
2.0 General
2.0.0
DHW Set point
Water set point temperature in DHW mode during comfort periods
°C
40 - 65 (Combi)
60
2.0.2
Gas Type
0 = Nat Gas
0 - 2
0
1 = LPG
2 = G230
2.0.3
Maximum water temp
Maximum absolute water temperature
°C
80 - 90
80
2.0.4
Altitude
Parameter for altitude compensation
m
0 - 7000
0
2.0.5
Fan inc. Percentage
Percentage of fan speed increase when reaching ionisation threshold
%
0 - 25
Do Not Change
2.0.6
T-Gradient
Gradient Function
°C/min
0 - 15
5
2.1 Free
2.1.7
Pump continuous running
0 = Disabled
0 - 1
0
1 = Enabled
2.1.8
Pump mode max DHW
Max pump speed during DHW burning cycle
%
pump mode min - 100% 90
2.2 Settings
2.2.4
Thermoregulation
Thermoregulation function enable 0 = OFF 1 = ON
0 - 1
1
2.2.7
Boiler Hybrid
Used to set the boiler as a part of a hybrid system
0 - 1
0
(Energy manager presence detection)
2.2.8
Boiler Version
Type of boiler selection
0 - 2
0
0 = Combi
1 = Storage with NTC
2 = Storage with Thermostat
2.3 Central Heating - 1
2.3.1
Max CH Adjustable
CH power level adjustable by engineer to the level required by the building
%
0 - 100
100
2.3.7
CH pump overrun
CH post circulation time
Min
0 - 16
1
2.4 Central Heating - 2
2.4.5
Max pump Modulation
Maximum pump speed in CH mode
%
min - 100
95
2.4.6
Min pump Modulation
Minimum pump speed in CH mode
%
25 - Max
50
2.4.9
External Temp correction
Offset of the Outdoor temperature reading
°C
-3 to +3
0
2.5 Domestic Hot Water
2.5.0
Comfort function
DHW pre-heating or storage heating operation mode selection
0 - 2
0
0 = Disabled
1 = Time Based
2 = Always active
2.6 Boiler Manual Settings
2.6.0
Manual mode activation
To enable or disable manual mode 0 = OFF 1 = ON
0 - 1
0
2.6.1
Pump Control
0 = OFF 1 = ON
0 - 1
0
2.6.2
Fan Control
0 = OFF 1 = ON
0 - 1
0
2.6.3
Diverter valve control
0 = OFF 1 = ON
0 - 1
0
2.6.7
External Pump
0 = OFF 1 = ON
0 - 1
0
27