79
Commissioning
Parameter adaption to the heating system
Value = mandatory setting
* adapt to the design characteristics of the heating system
** adapt to the comfort needs of the customer
Parameter
Name
Description
Factory
settings
Fix
Flow T
Basic thermoregulation
Room T
Only
Outdoor T
Only
Room + Outdoor
T
4
Zone 1 Parameters
4.1
Automatic winter mode
4.1.0
Automatic winter mode activation O = OFF - - - 1 = ON
0
**
**
**
**
**
4.1.1
Automatic winter mode threshold outside temperature
20°C
**
**
**
**
**
4.1.2
Automatic winter mode delay
time
adjustable time for the treshold
60 min. **
**
**
**
**
4.2
Zone 1 Settings
4.2.0
Zone temperature range
0 = Low Temp (LT)
1 = High Temp (HT)
1
*
*
*
*
*
4.2.1
Thermoregulation
0 = Fix Flow T
1 = Basic thermoregulation
2 = Room T Only
3 = Outdoor T Only
4 = Room + Outdoor T
0
0
1
2
3
4
4.2.2
Slope
LT: From 0.2 - 1.0
HT: From 0.4 - 3.5
0.6LT
1.3HT
*
*
*
*
*
4.2.3
Offset
LT: From -7°C to +7°C
HT: From -14°C to +14°C
0
0
*
*
*
*
*
4.2.5
Max T
LT: From 10°C to 45°C
HT: From 10°C to 90°C
LT 45
HT 85
*
*
*
*
*
4.2.6
Min T
LT: From 10°C to 45°C
HT: From 10°C to 90°C
LT 20
HT 40
*
*
*
*
*
4.2.8
Quick night setback
0 = OFF / 1 = ON
0
*
*
*
*
*
4.2.9
Heat reguest mode
0 = Standard
1 = RT Time Programs Exclusion
2 = Forcing Heat Demand
0
**
**
**
**
**
4.3
Zone 1 Diagnostics
4.3.0
Room T
°C
4.3.1
Room T setpoint
°C
4.3.2
Flow temperature
°C
4.3.3
Return temperature
°C
4.3.4
Heat request Z1
0 = OFF, 1 = ON
4.3.5
Pump status
0 = OFF, 1 = ON
4.3.9
Heating rate