7
Product description
Technical data
ErP data
Tipe ATAG XL F
75
105
125
150
180
210
Permit
CE0063CT3449
Category
GB: II2H3P
Heat exchanger type
iConXL1
iConXL2
iConXL1
iConXL1
iConXL1
iConXL1
iConXL1
iConXL2
iConXL2
iConXL2
Output
G20
Full load
80/60°C
kW
65,4
90,2
110,8
130,5
155,5
180,3
40/30°C
kW
72,0
99,0
122,2
142,4
170,9
197,4
Low load
80/60°C
kW
14,6
18,1
14,7
14,6
14,6
18,1
40/30°C
kW
16,1
19,9
16,2
16,0
16,1
19,8
G31
Full load
80/60°C
kW
65,4
90,2
110,8
130,5
155,5
180,3
40/30°C
kW
72,0
99,0
122,2
142,4
170,9
197,4
Low load
80/60°C
kW
23,2
34,3
23,3
23,2
23,2
34,3
40/30°C
kW
25,6
37,7
25,7
25,3
25,5
37,6
Input
G20
Full load
kW
66,7
92,3
112,8
133,2
158,8
184,5
Low load
kW
14,9
18,5
14,9
14,9
14,9
18,5
G31
Full load
kW
66,7
92,3
112,8
133,2
158,8
184,5
Low load
kW
23,6
35,0
23,6
23,6
23,6
35,0
Gas consumption
G20
Full load
m
3
/h
7,06
9,77
11,94
14,10
16,80
19,52
Low load
m
3
/h
1,57
1,95
1,57
1,57
1,57
1,95
G31
Full load
m
3
/h
2,72
3,76
4,60
5,43
6,47
7,52
Low load
m
3
/h
0,96
1,43
0,96
0,96
0,96
1,43
Boiler efficiency
Full load
80/60°C
%
98,0
97,7
98,2
98,0
97,9
97,7
Full load
40/30°C
%
108,0
107,3
108,3
106,9
107,6
107,0
Low load
80/60°C
%
98,3
97,9
98,5
98,3
98,2
97,9
Low load
40/30°C
%
108,4
107,6
108,7
107,3
107,9
107,3
Gas type
Natural gas or Propane gas
CO
2
natural gas
min./max
Vol. %
8,7 / 9,0
CO
2
propane gas
min./max
Vol. %
10,2 / 10,8
O
2
natural gas
min./max
Vol. %
5,3 / 4,8
NOx class
6
6
6
6
6
6
Max. flue gas temperature
80/60°C
61
71
62
61
72
71
Mass flow of flue gas
kg/h
119,8
165,8
202,6
239,3
285,3
331,5
Overpressure at boiler output
max
Pa
156
243
143
200
215
265
Water volume in heating circuit
max
l
9,3
13,9
16,8
16,8
21,3
25,8
Weight
kg
73
80
127
127
132
140
Gas pressure nominal
mbar
20
Gas pressure min / max
mbar
17 / 25
Water pressure
min./max
bar
1* / 6 bar (*0,5bar: boiler shut off limit)
Voltage / frequency
min./max
Volt/Hz
230 / 50
Max power consumption
W
155
250
260
375
428
430
Power consumption part load
W
53
53
55
55
51
51
Power consumption stand-by
W
5
5
6,8
6,8
6,8
6,8
Height/Width/Depth
mm
1100/530/595 1100/530/675
1100/690/595
1100/690/675
Gas Coupling
R
Rp 1 1/4"
Flow / Return Coupling
R
Rp 2"
Fluegas Outlet
Diameter
DN
100
100
100
100
130
130
Air inlet
Internal
in mm
100
100
100
100
130
130
Condensate tube
External
in mm
35
35
35
35
35
35
Type ATAG XL F
75
105
125
150
180
210
ErP data according to 2010/30/EU and 811/2013/EU
Seasonal room-heating energy efficiency class
A
Nominal heat output
P
n
(kW)
65
90
111
131
156
180
Seasonal room-heating energy efficiency class
η
s
(%)
93
93
93
93
93
93
Annual energy consumption
Q
HE
(GJ)
202
280
342
404
482
558
Noise output level, inside
L
WA
(dB)
65
60
67
70
67
63
At rated heat output and high-temperature regime (80/60°C)
P4 (kW)
65,3
90,2
110,8
130,6
155,6
180,3
At 30 % of rated heat output and low-temperature regime (36/30°C)
P1 (kW)
21,8
30,2
37,0
43,7
52,0
60,4
At rated heat output and high-temperature regime (GCV)
η4 (%)
88,2
87,9
88,4
88,2
88,2
87,9
At 30 % of rated heat output and low-temperature regime (GCV)
η1 (%)
98,3
98,2
98,4
98,3
98,2
98,2
At full load
elmax (kW)
0,137
0,120
0,314
0,418
0,464
0,450
At part load
elmin (kW)
0,045
0,095
0,066
0,071
0,109
0,099
In standby mode
Psb (kW)
0,005
0,005
0,007
0,007
0,007
0,007
Standby heat loss
Pstby (kw)
0,086
0,075
0,079
0,079
0,100
0,141