GB 27
FAULTS
Symptom
Possible cause
Solution
A burner does not ignite.
Burner parts dirty/damp.
Main gas tap closed.
Fault in the gas network.
Gas bottle or tank is empty.
Wrong type of gas used
(where bottled gas is used).
Control knob not kept pres-
sed in far enough.
Clean and dry the burner
parts, making sure that the
outflow holes are open.
Open the main gas tap.
Check with your gas supplier.
Connect a new gas bottle or
have the tank filled.
Check that the gas used is
suitable for the appliance.
If this is not correct, contact
the installation company you
employed.
Keep the control knob pres-
sed in far enough between
full and low. For fi rst use, this
may take longer on account
of the gas supply.
The burner does not burn
evenly.
Burner parts incorrectly
installed.
Burner parts dirty or damp.
Wrong type of gas used
(where bottled gas is used).
Assemble the burner parts
using the centring ridges.
Clean and dry the burner
parts, making sure that the
outflow holes are open.
Check that the gas used is
suitable for the appliance.
The burner goes out after
igniting.
Control knob not kept pres-
sed in long enough
Keep the control knob pres-
sed in for at least 5 seconds.
Summary of Contents for CG9271MB
Page 36: ...NL 36...
Page 70: ...GB 36...