58 / 67
METER INSTRUCTION
8. Press the START/STOP key to begin exercise.
NOTE:
1. WATT = TORQUE (KGM) * RPM * 1.03
2. In this program, the WATT value will keep constant value. It means that if you peddle quickly, the
resistance level will decrease and if you peddle slowly, the resistance level will increase. Always try to
keep you in the same watt value.
Body Fat Program: Body Fat
Program 24
is a special program design to calculate users’ body fat ratio and to offer a specific
loading profile for users. There are 3 body types divided according to the FAT% calculated.
Type1: BODY FAT% > 27
Type2: 27
≧
BODY FAT%
≧
20
Type3: BODY FAT % < 20
The computer will show the test results of FAT PERCENT
Operations:
1. Use UP/DOWN keys to select the BODY FAT (P24) program.
2. Press the ENTER key to enter your workout program.
3. The HEIGHT will flash and you can press UP or DOWN keys to set your HEIGHT. Press ENTER
key to confirm your HEIGHT. The default HEIGHT is 170cm or 5’07” (5feet 7 inches).
4. The WEIGHT will flash and you can press UP or DOWN keys to set your WEIGHT. Press ENTER
key to confirm your WEIGHT. The default WEIGHT is 70kgs or 155lbs.
5. The GENDER will flash and you can press UP or DOWN keys to select your sex. Number 1 means
man and number 0 means female. Press ENTER key to confirm your Gender. The default sex is 1
(MAN).
6. The AGE will flash and you can press UP or DOWN keys to set your AGE. Press ENTER key to
confirm your AGE. The default AGE is 35.
7. Press the START/STOP key to begin body fat measurement. If the window show E on the window,
please make sure your hands are attached well on the grips or the chest belt is touch well on your
body. Then press the START/STOP key again to begin body fat measurement.
8. After finished your measurement, the computer will show the values of FAT PERCENT on the LCD
display.
9. Press START/STOP key to begin exercise.
Operation guide:
1. Sleep Mode:
The computer will enter the sleep mode when there is no signal input and no keys be pressed
after 4 minutes. You can press any key to wake up the computer.
Error Message:
E1 (ERROR 1):
Normal state
: During workout, when the monitor did not get the count signal from the gear motor
more than 4 seconds and check under successive 3 times then the LCD will show E1.
Power on state
: The gear motor will return to zero automatically, when the signal of motor cannot be
detected for more than 4 seconds then the gear motor’s driver will be cut off immediately and show
the E1 on the LCD display. All the other digital and function mark are blank, and the output signals are
cut off also.
E2 (ERROR 2): When the monitor read the memory data, if the I.D. code is not correct or the memory
IC damages then the monitor will show E2 immediately at power on.
E3 (ERROR 3): After 4 seconds by start mode, the computer detects the faulty motor did not leave the
zero point then the LCD bar displays “E3”.
Summary of Contents for C22_P
Page 1: ...Version J BP BEDIENUNGSHANDBUCH C22_P ...
Page 6: ...6 67 EXPLOSIONSZEICHNUNG ...
Page 7: ...7 67 EXPLOSIONSZEICHNUNG ...
Page 43: ...EXPLODED DIAGRAM ...