6-18
Chapter 6: RAID configuration
6.2.5
Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected virtual drive. The
utility can automatically detect and/or detect and correct any differences in data redundancy
depending on the selected option in the
Objects > Adapter
menu.
The
Check Consistency
command is available only for virtual drives included in a RAID 1
or RAID 10 set.
Using the Check Consistency Command
To check data consistency using the
Check Consistency
command
1.
From the
Management Menu
, select
Check Consistency
, and then press <Enter>.
2.
The screen displays the available RAID set(s) and prompts you to select the virtual
drive to check. Press <Space> to select the virtual drive from the
Virtual Drive
sub-
menu, and then press <F10>.
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
CC Of VD(s)
LSI Software RAID Configuration Utility Ver C.05 Feb 17, 2012
BIOS Version A.10.09231523R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Select VD
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64 KB ONLINE
Virtual Drives
Virtual Drive 0
LSI Software RAID Configuration Utility Ver C.05 Feb 17, 2012
BIOS Version A.10.09231523R
SPACE-(De)Select, F10-Check Consistency
Summary of Contents for RS320Q-E7 RS12
Page 1: ...2U Rackmount Server RS320Q E7 RS12 User Guide ...
Page 27: ...2 7 ASUS RS320Q E7 RS12 8 Insert the load lever under the retention tab ...
Page 48: ...Chapter 3 Installation options 3 6 ...
Page 64: ...4 16 Chapter 4 Motherboard information ...
Page 94: ...5 30 Chapter 5 BIOS setup ...
Page 156: ...A 2 Appendix A Reference information A 1 P8BH block diagram ...