ASUS PXL-S30R
2-15
Activating an array
If an array is removed from one controller/computer or moved to another, the
array is considered inactive. When you add the array back to the system, you may
reactivate the array.
To activate the array:
1. Follow steps 1~2 of the section
Viewing volume properties
.
2. From the screen, press <F2> to select <Activate Array>.
3. Press <Y> to activate, or <N> to cancel.
Esc=Abort/Exit ArrowKeys=Select Item -/+ =Change [Item]
Home/End =Select Item Enter=Execute <Item>
F2 =Menu
RAID Properties Array: IM SCSI ID: 8 Size(MB): 70008
SCSI Device Identifier Array Hot Status Predict Size
ID Disk? Spare Failure (MB)
8 FUJITSU MAT3073NC 0107 Yes No Primary No 70008
9 FUJITSU MAT3073NC 0107 Yes No Out of Sync No 70008
10 FUJITSU MAT3073NC 0107 --- Yes
Ok No 70008
LSI Logic MPT SCSI Setup Utility Version MPTBIOS-IME-5.10.03
<Next Array>
<Delete Array>
<Add/Delete Hot Spare>
<Activate Array>
Synchronizing the array
Synchronizing the array allows the utility to resynchronize data on the mirrored
disk in the array. This procedure is seldom required because data synchronization
is automatically done during normal operation. To synchronize the array, select
Synchronize Whole Mirror
from the main menu to start the synchronization.
Esc = Abort/Exit ArrowKeys=Select Item -/+ =Change [Item]
Home/End =Select Item Enter=Execute <Item>
LSI Logic MPT SCSI Setup Utility Version MPTBIOS-IME-5.10.03
Adapters Properties
Adapter PCI Dev/
Bus Func
1020/1030 2 10
<Device Properties>
<RAID Properties>
<Synchronize Whole Mirror>
Host SCSI ID
[ 7]
SCSI Bus Scan Order
[Low to High (0..Max)]
Removable Media Support
[None]
CHS Mapping
[SCSI Plug and Play Mapping]
Spinup Delay (Secs)
[ 2]
Secondary Cluster Server
[No]
Termination Control
[Auto]
<Restore Defaults>