2-6
Chapter 2: RAID configuration
6. The
Create New Array
screen shows the disks you can add to make up the IM
volume. Use the arrow key to select a disk, then move the cursor to the
RAID
Disk
column. To include this disk in the array, press <+>, <->, or <Space>.
You may also specify the Hot Spare disk here. Select the disk, then move the
cursor to the
Hot Spr
column, then press <+>, <->, or <Space>.
By default, the
RAID Disk
field shows
No
before array creation. This field is
grayed out under the following conditions:
• The disk does not meet the minimum requirements for use in a RAID array.
• The disk is not large enough to mirror existing data on the primary drive.
• The disk has been selected as the Hot Spare for the RAID array.
• The disk is already part of another array.
Esc = Exit Menu F1/Shift+1 = Help
SPACE/+/- = Select disk for array or hot spare C = Create array
LSI Corp Config Utility v6.20.00.00 (2007.12.04)
Create New Array -- SAS1064E
Array Type: IM
Array Size(MB): ------
Slot Device Identifier RAID Hot Drive Pred Size
Num
Disk Spr Status Fail (MB)
0
SEAGATE ST336754SS 0003 [No] [No] ------- ---- 35003
1
SEAGATE ST336754SS 0003 [No] [No] ------- ---- 35003
2
SEAGATE ST336754SS 0003 [No] [No] ------- ---- 35003
3
SEAGATE ST336754SS 0003 [No] [No] ------- ---- 35003