GigaX Series L2 Managed Switch User’s Guide
92
The
Policy Edit
page is used to create policy actions. The classes that
are added to a policy must have the same match type. A policy can only
have maximum 6 classes. The following fields are available:
•
Class ID: select an existed Class ID.
•
DSCP: select a DSCP value. Incoming packets that match the class
ID will be specified the DSCP value to the class ID
•
Traffic Rate: set the traffic rate. The valid value is from 1 to 125. For
Gigabit Ethernet ports, the value will be multiplied by 8. For example,
set traffic rate to 10. Then the traffic rate of Fast Ethernet ports is 10
Mbps, but for Gigabit Ethernet ports, the traffic rate is 80Mbps.
•
Traffic Burst Size: select a traffic burst size. The minimum size of
Fast Ethernet ports is 4K. For Gigabit Ethernet ports, traffic burst
size will be multiplied by 8. For example, set traffic burst size to 4K.
Then the burst size of Fast Ethernet ports is 4K Bytes, but for Gigabit
Ethernet ports, the burst size is 32K Bytes.
•
Exceed Action: select exceed action. If the exceed action is not
'None', user must enter or select a value for traffic rate and traffic
burst size.
•
Exceed DSCP: if exceed action is ‘DSCP’, user must select an
exceed DSCP value.
Summary of Contents for GIGAX 2048
Page 1: ...GigaX Series L2 Managed Switch User Guide GigaX Series Layer 2 Managed Switch User Guide ...
Page 31: ...GigaX Series L2 Managed Switch User Guide Figure 12 Home page GigaX 2024 ...
Page 36: ...GigaX Series L2 Managed Switch User s Guide 36 Figure 16 Management ...
Page 38: ...GigaX Series L2 Managed Switch User s Guide 38 Figure 17 IP Setup ...
Page 50: ...GigaX Series L2 Managed Switch User s Guide 50 Figure 26 Mirroring page GigaX 2024 ...
Page 55: ...GigaX Series L2 Managed Switch User Guide Figure 31 Dynamic Address ...
Page 63: ...GigaX Series L2 Managed Switch User Guide Figure 38 Community Table ...
Page 77: ...GigaX Series L2 Managed Switch User Guide Figure 49 Port Access Control ...
Page 80: ...GigaX Series L2 Managed Switch User s Guide 80 Figure 51 RADIUS ...
Page 90: ...GigaX Series L2 Managed Switch User s Guide 90 Figure 57 Class Set ...
Page 95: ...GigaX Series L2 Managed Switch User Guide Figure 60 Policy Attach ...
Page 99: ...GigaX Series L2 Managed Switch User Guide Figure 63 Traffic comparison GigaX 2024 ...
Page 104: ...GigaX Series L2 Managed Switch User s Guide 104 Figure 67 CLI interface ...
Page 129: ...GigaX Series L2 Managed Switch User Guide CLI command snmp snmpv3 usmuser retrieve ...