GigaX Series L2 Managed Switch User Guide
3. Make sure the settings of your terminal emulation software as
follows:
a)
Choose the appropriate serial port number
b)
Set the data baud rate to 115200 (or 9600 on some models)
c)
Set the data format to no parity, 8 data bits and 1 stop bit
d) No
flow
control
e)
Set VT1000 for emulation mode
4. After setting up the terminal, you can see the prompt “(ASUS)%” on
the terminal.
5. Type “login” to access the command line interface. The default user
name is “admin”. Skip the password by pressing
<Enter>
.
You can change the password at any time through CLI (see
section 5.3.1). To protect your switch from unauthorized
access, you must change the default password as soon as
possible.
6. Follow these steps to assign an IP address to the switch:
a)
Type “net interface ip sw0 <your ip address> <your network
mask>”. For example, if your switch IP is 192.168.10.1 and the
network mask is 255.255.255.0. Then you should type “net
interface ip sw0 192.168.10.1 255.255.255.0”.
b)
If the switch has to be managed across networks, then a
default gateway or a static route entry is required. Type “net
route static add 0.0.0.0 <your network gateway IP> 0.0.0.0 1”
as your default route entry, as shown in Figure 6.
Figure 6.
Login and IP setup Screen
Summary of Contents for GIGAX 2048
Page 1: ...GigaX Series L2 Managed Switch User Guide GigaX Series Layer 2 Managed Switch User Guide ...
Page 31: ...GigaX Series L2 Managed Switch User Guide Figure 12 Home page GigaX 2024 ...
Page 36: ...GigaX Series L2 Managed Switch User s Guide 36 Figure 16 Management ...
Page 38: ...GigaX Series L2 Managed Switch User s Guide 38 Figure 17 IP Setup ...
Page 50: ...GigaX Series L2 Managed Switch User s Guide 50 Figure 26 Mirroring page GigaX 2024 ...
Page 55: ...GigaX Series L2 Managed Switch User Guide Figure 31 Dynamic Address ...
Page 63: ...GigaX Series L2 Managed Switch User Guide Figure 38 Community Table ...
Page 77: ...GigaX Series L2 Managed Switch User Guide Figure 49 Port Access Control ...
Page 80: ...GigaX Series L2 Managed Switch User s Guide 80 Figure 51 RADIUS ...
Page 90: ...GigaX Series L2 Managed Switch User s Guide 90 Figure 57 Class Set ...
Page 95: ...GigaX Series L2 Managed Switch User Guide Figure 60 Policy Attach ...
Page 99: ...GigaX Series L2 Managed Switch User Guide Figure 63 Traffic comparison GigaX 2024 ...
Page 104: ...GigaX Series L2 Managed Switch User s Guide 104 Figure 67 CLI interface ...
Page 129: ...GigaX Series L2 Managed Switch User Guide CLI command snmp snmpv3 usmuser retrieve ...