Chapter 2: Hardware Setup
2-30
2.8
Removable/optional components
You may need to remove previously installed system components when installing or removing
system devices. You may need to install the optional components into the system. This
section tells how to remove/install the following components:
1.
System fans
2.
Redundant power supply units
Ensure that the system is turned off before removing any components.
2.8.1
System fans
To uninstall the system fans:
1.
Hold the system fan by the notches (A),
then press the latch inwards (B) to release
the system fan from the fan cage.
2.
Lift the fan then set it aside.
3.
Repeat steps 1 to 2 to uninstall the other
system fans.
To reinstall the system fans:
1.
Insert the fan into the fan cage. Ensure the
fan connector is seated firmly within the
cable holder.
cable holder