AP100 Hardware Reference Guide
29
III. Power Information
III. Power Info.
Protection
Over Power Protection (OPP):
105% to 140%
Over Voltage Protection (OVP):
+5V:
5.58V to 6.82V
+12V:
12.8V to 14.50V
+3.3V:
3.7V to 4.80V
Short Protection:
All outputs shorted to ground are protected.
Efficiency:
70% Min
Environment
Ambient Operation Temperature: 0˚C to 50˚C
Ambient Operation Relative Humidity: 20% to 80%
Insulation Resistance:
Input to Ground
50M
Input to Output
50M
Dimension: LxWxH:
150mm x 140mm x 86mm
Weight:
1.8Kgs
Hi-Pole
Input to Output
1,800VAC
3Sec
Input to Ground
1,800VAC
3Sec
Certifications
Approval Date
Safety Approval
Certificate Number
1997-08-14
CE (Nemko)
9708001E
1997-08-28
CB
4052
1997-08-28
VDE
95325
199X-XX-XX
UL
(pending)
199X-XX-XX
CSA
(pending)
1997-08-27
Nemko
199734114
1997-09-08
Semko
9736061-06
1997-09-03
Demko
306976
1997-09-02
Fimko
197014-06
Power Supply