28
AP100 Hardware Reference Guide
III. Power Information
III. Power Info.
Power Supply
III. Power Information
Power Supply (ST-251HR)
Input
Output
DC Output Cond.: Load (Amp)
Min
Nom
Max Ripple(mV) Noise(mV)
+3.3V*
1.5
7.50
15.0
50
100
+5.0V*
2.0
10.0
20.0
50
100
+12V
1.2
6.00
12.0
120
240
-05V
0.0
0.25
0.50
100
200
-12V
0.0
0.25
0.50
120
240
+5VSB
0.0
0.50
1.00
50
100
(* +3.3V and +5V Total Output Limit: 100W)
Output Rating:
+5V
+12V
+3.3V
-12V
-5V
Max
+5.25V
+12.60V
+3.465V
-12.60V
-5.25V
Min
+4.75V
+11.40V
+3.135V
-11.40V
-4.75V
Tolerance
±5%
±5%
±5%
±5%
±5%
Remote On/Off Control: PS-On
TTL Low/Close
DC Outputs are to be Enabled
PS-Off
TTL High/Open
DC Outputs are to be Disabled
Line Regulation:
+3.3V:
1% Max
+5.0V:
1% Max
Load Regulation:
+3.3V:
5% Max
+5.0V:
5% Max
Cross Regulation:
+5V 20A: 4.75V Min and +12V 1.2A: 12.60V Max
+5V 2A: 5.25V Max and +12V 12A: 11.40V Min
Temperature Arrangements:
1% Max
Slow Start Time:
5ms to 50ms
Power Good Time:
100ms to 500ms
Hold up Time:
20ms Min (at Nominal Input)
Power Fail Time:
1ms Min (at Nominal Input)
Input Current
Input 115VAC/Max
6A (Full Load)
Input 230VAC/Max
4A (Full Load)
Frequency
50Hz - 60Hz
50Hz - 60Hz
In-Rush Current Max.
Input 115VAC/Max
79A (Full Load)
Input 230VAC/Max
79A (Full Load)
Voltage
Minimum Nominal
Maximum
Low Range 100VAC
115VAC
132VAC
High Range 180VAC
230VAC
264VAC