background image

8.

 

Driver Connection to Stepper Motors

 

 

The P808 driver can drive any 4, 6 or 8 lead hybrid stepper motors. The following diagrams illustrate 
connection to various kinds of motor leads: 

 

                          

 

Note that when two coils are connected in parallel, coil inductance is reduced by half and motor speed 
can be significantly increased. Serial connection will lead to increased inductance and thus the motor 
can be run well only at lower speeds. 

 
 

9.

 

Connection Diagram 

 

A complete stepping system should include stepping motor, stepping driver, power supply and 
controller (pulse generator). 
A typical connection is shown below: 

 

  -        

 

 

 

Astrosyn International Technology Ltd, The Old Courthouse, New Rd Ave, Chatham, Kent   ME4 6BE, England

 

Tel: +44(0)1634 815175                 Fax: +44(0)1634 826552 

 

Summary of Contents for P808

Page 1: ...User Manual Model P808 High Performance Microstepping Driver Astrosyn International Technology Ltd The Old Courthouse New Rd Ave Chatham Kent ME4 6BE England Tel 44 0 1634 815175 Fax 44 0 1634 826552...

Page 2: ...t control for less motor heating z 14 selectable step resolutions in decimal and binary z Microstep resolutions up to 51 200 steps rev z Suitable for 4 6 or 8 lead motors z Over current over voltage a...

Page 3: ...this signal is used for enable disable high level for enabling driver and low level for disabling driver Usually left unconnected enabled Remark 1 Pul dir is the default mode internal jumper JMP1 can...

Page 4: ...r and ground in the wrong way it will damage the driver 5 Driver Voltage and Current Selection This driver can match small medium size step motors NEMA 17 23 34 and 42 To achieve good driving results...

Page 5: ...ff Current Setting The first three bits SW1 2 3 of the DIP switch are used to set the current during motion dynamic current while SW4 is used to select standstill current P808 DIP Selection for curren...

Page 6: ...lt in high speed optocoupler and can accept signals in the format of line driver open collector or PNP output Line driver differential signals are suggested for reliability In the following figures co...

Page 7: ...and motor speed can be significantly increased Serial connection will lead to increased inductance and thus the motor can be run well only at lower speeds 9 Connection Diagram A complete stepping syst...

Page 8: ...be established at least 2 s before the first pulse of the next pulse train Please examine the timing diagrams of the three control signals as follows 11 Dimensions External dimensions are shown in mm...