INDICATOR LIGHT 

An optional indicator light (LED) can be added to show the status of the safety sequence (on vehicles equipped with a manual transmission), of the safety 
system, the antitheft system or of the Valet Mode. 
See ‘Indicator Light’ in the ‘Safety System’ Section. 
The following table shows the codes displayed by the indicator light when performing the safety sequence. 
 

Repeated flashes 

Phase or Status 

3 double flashes 

Start of sequence. 

2 double flashes 

Door open. 

1 double flash 

Door closed (waiting for engine to stop). 

1 single flash 

Valid safety sequence (system is ready to receive a start command). 

Fast (10 sec.) 

Invalid sequence (sequence must be started over from beginning). 

 

UTILITY COMMANDS 

These commands allow you to control most of the vehicle’s accessories depending on what was connected during the installation (headlights, defroster, etc.). For 
more information, check with your technician. 
To activate these functions, simultaneously press the buttons as shown in the following table. (Fill-up the blanks) 

Commands Buttons 

Corresponding accessory 

Duration 

UTILITY 1 * 

 + 

 

 

 

UTILITY 2 

 + 

 

 

 

The accessory associated to each command is activated for the duration set at time of installation. 
The delay can be cancelled by repeating the command. 

Programmable at time of installation: the “trunk” command can activate utility 1. 

CAR FINDER   +   

Press the 

 and 

 buttons simultaneously. 

This function sounds the horn (short melody) and flashes the parking lights so you can locate your vehicle in a large parking lot. 

PANIC 

To activate the panic mode, press and hold either the 

 or the 

 button for more than 4 seconds. 

This command activates all deterrents that are connected to the system, parking lightshornsiren and dome light for 30 sec. 

 or 60 sec. 

, depending 

on programming made during installation. 
Panic mode is used to attract attention if you are experiencing difficulties. 
If you are inside the vehicle when Panic Mode is activated, press on the brake pedal to lock doors (optional connections required) and neutralize antitheft (60 

sec. if doors were already unlocked). As long as the cycle is not over, applying the brakes resets the sequence from the beginning every time. 
This command will not be executed if the engine is kept running by the ignition key. Use the stop command to abort panic mode. 

 

 

Summary of Contents for R SS-5225

Page 1: ...5225 For all hybrid gas and diesel powered vehicles 2 WAY SST 5 button REMOTE STARTER with LCD display CONSULT SAFETY PRECAUTION SECTION BEFORE USING THIS PRODUCT SOME FEATURES MAY REQUIRE ADDITIONAL...

Page 2: ...protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruct...

Page 3: ..._____ 3 PREPARING SYSTEM 3 SAFETY SEQUENCE FOR MANUAL TRANSMISSION VEHICLES 4 THE 2 WAY REMOTE CONTROL _____________________________________________________________________ 5 THE BATTERY______________...

Page 4: ...you have your remote starter checked annually Contact a dealer in your area All users of the vehicle should be aware of the safety precautions and operation procedures Make sure that the warning stic...

Page 5: ...ine running 5 Exit the vehicle 6 Within 60 seconds close all doors 7 The system will stop the engine except if Turbo Mode or Continuous Mode is active The parking lights blink once 1 to confirm the se...

Page 6: ...electronic devices with magnetic fields or crowded parking lots If no confirmation is received in a given location move away from the sources of interference and activate the Status command on the sid...

Page 7: ...damage and or reduce battery life Avoid placing the remote control in areas exposed to extreme cold or heat direct sunlight when charging the battery BATTERY LIFE The remote control has many features...

Page 8: ...taining to the security system s functions 1 Locked without Valet 12 Car Door Trigger 2 Locked with Valet 13 Hood Trigger 3 Unlocked without Valet 14 Trunk Trigger 4 Unlocked with Valet 15 Sentinel mo...

Page 9: ...t confirmation is sent as many times as the command is repeated so you are sure that the system has received the command The audible confirmation is also repeated siren or horn depending on programmin...

Page 10: ...on is Active Inactive START COMMANDS STARTING THE ENGINE To start the engine press the button The system automatically adjusts the ignition duration for your type of vehicle gas or diesel the parking...

Page 11: ...may be set to your convenience To access the remote control programming mode press the button located on the side of the remote and hold it for four 4 seconds The remote will emit one long tone Releas...

Page 12: ...that either the vehicle or the remote could not receive the command ENGINE RUNTIME Your engine will stop automatically after a preset runtime 4 min 8 min or 18 min depending on settings during install...

Page 13: ...commands to stop the hood is open the brakes are applied the engine is over revving if programmed Enable at installation the alarm detects intrusion the main switch is OFF the safety sequence is not...

Page 14: ...1 5 SEC ON REMOTE ONLY 1 BEEP FOR CAR 1 2 BEEPS FOR CAR 2 3 BEEPS FOR CAR 3 OR OR COMMANDS FOLLOWED BY AN ASTERISK APPLY ONLY TO COMMAND UNITS EQUIPPED WITH A SECURITY SYSTEM THIS COMMAND TERMINATES...

Page 15: ...bourhood the pre alarm mode is triggered three seconds before the alarm condition to give you time to disarm the system In this mode the parking lights siren and dome light go on and off intermittentl...

Page 16: ...on siren chirps once indicating that the system will arm after 25 seconds After this delay the alarm is armed and a second confirmation the siren chirps once and the parking lights flash once is sent...

Page 17: ...disarmed with violation detected Indicator light indicates cause of alarm condition INDICATOR LIGHT The Indicator light flashes a specific number of times to indicate different alarm conditions when a...

Page 18: ...goes out and the parking lights flash twice to confirm that the mode was disabled Notes If you perform both sequences one after the other you need to pause for 3 seconds between the two sequences The...

Page 19: ...onding accessory Duration UTILITY 1 UTILITY 2 The accessory associated to each command is activated for the duration set at time of installation The delay can be cancelled by repeating the command Pro...

Page 20: ...erefore if you want to add a new remote all the old ones must be reprogrammed as well One or more remote transmitters can be added To do this you must follow these steps Before all select the pairing...

Page 21: ...S 1 Carry out the safety sequence then remote start the engine to confirm that the safety sequence is valid Make sure not to apply the brakes 2 Release the parking brake The engine must stop immediate...

Page 22: ...een received See table in CONFIRMATION section VIOLATION A Violation means that a situation causes a protection zone to generate an alarm condition For example a door was opened etc DOME LIGHT DURATIO...

Reviews: