2.2.

 

Remarks 

 

Keep  in  mind  that  the  BatFlex  system  uses  a  static  IP  Version  4  configuration.  This  requires  the  user  to  choose  an  IP 
separately for each device. 

 

The IP is updated as soon as the configuration menu closes. Restarting the device is not necessary. 

 

Network IPs are usually managed by a DHCP Server. Therefore the BatFlex IP must not be in the specified range of the DHCP. 
Otherwise IP address collisions may occur. Usually there is a static IP range where one should set up the BatFlex system with. 

 

It’s advised to avoid bigger networks (for example global company networks) especially in case of very long measurements. 
Unexpected or unavoidable maintenance of the network could cause measurement data loss. 

2.3.

 

Card Types 

The BatFlex Device is designed as amodular System where measurement cards can be replaced whenever the device is turned off. The 
onboard microprocessor is able to recognize the new configuration on the next power up. 

2.4.

 

Overview 

Card Type 

Card Function 

BatFlex FPGA Card 

This card contains the onboard data processing controller and the network adapter. 

BatFlex Reference Card 

This card contains a high precision, thermally regulated voltage reference which is used periodically to 
calibrate measurement cards. 

BatFlex Small Card 

This card is a measurement card for small currents up to 24 mA. The full specification can be found in 
chapter 2.5.4 

BatFlex Small Dual Card 

This  card  is  a  compound  consisting  of  two  stacked  BatFlex  Small  cards.  This  allows  to  use  up  to  8 
channels with a single card slot. The full specification can be found in chapter 2.5.4. 

 

 

Summary of Contents for BAT-FLEX

Page 1: ...e specifications without notice Bat FLEX Manual 1 19 AD 10069 007 Rev 03 BAT FLEX Manual Rev Remarks changes created checked released 01 Initial ported RT 01 03 13 AST 01 03 13 AST 01 03 13 03 Correct...

Page 2: ...ard 7 2 5 3 BatFlex Small Dual Card 7 3 CCCC Setup 8 3 1 Preparation 8 3 2 Communication Setup 8 3 3 CCCC Overview 9 4 Set up the Measurement Program 10 4 1 Introduction 10 4 2 Measurement Flow 11 4 3...

Page 3: ...cription how to set the device IP can be found in the BatFlex FPGA Card Menu Guide Ethernet User PC 1 2 Direct Connection Please read Appendix A How to set up a static IP for further instructions User...

Page 4: ...ected or unavoidable maintenance of the network could cause measurement data loss 2 3 Card Types The BatFlex Device is designed as amodular System where measurement cards can be replaced whenever the...

Page 5: ...by turning the wheel to the left or to the right Selections are confirmed by pressing the wheel The SD card slot can be used to upgrade the firmware of the device USB and JTAG are for service and deb...

Page 6: ...ice FPGA IMG from SD A new FPGA image will be transferred from the SD card to the device This is a major update which means that the entire software is renewed Firmware from SDCard The FPGA boots up s...

Page 7: ...gnation 2 5 4 1 Specification Channels Details Value Unit Number of channels 8 Pcs Current measurement Details Value Unit Resolution 188 uA 100 pA 750 uA 400 pA 3 mA 1 5 nA 24 mA 12 nA Accuracy full s...

Page 8: ...needs to be restarted On startup the application searches for a viable device on the Network If the device is not yet configured the first action after the main window shows up is to get into the comm...

Page 9: ...esn t switch automatically to constant current mode The range can be chosen by clicking on I and selecting the appropriate range in the dropdown menu Output Modes Constant voltage By clicking on Uout...

Page 10: ...is created by the CCCC Software during a measurement It contains the measurement data recorded by the device Log File log This File contains all the events that took place during the measurement For e...

Page 11: ...en move from position to position during the execution Each step has its unique ID and can be configured with individual parameters It s also possible to jump between the steps by setting conditions t...

Page 12: ...ostatic Step This step implements a galvanostat or current source Its main purpose is to keep the current through the cell constant disregarding changes in the load itself This step offers a condition...

Page 13: ...channel has to be selected After that the measurement window can be opened The measurement window contains control elements to start stop and pause the data recording as well as a table with the curre...

Page 14: ...irst step is a counter step which sets the cycle counter to one The following two steps are galvanostatic steps which charge discharge with a constant current until the defined end voltage is reached...

Page 15: ...Tool offers two main methods to display the data as a CV diagram Current Voltage or as a time dependent diagram There are many customizable parameters to get the best view on the desired data 7 Expor...

Page 16: ...twork card with up to date network drivers Open the Network and Sharing Center This can be found in the Control Panel under Network and Internet A Control Panel can be opened by pressing Windows R the...

Page 17: ...ddress This will activate the input fields One should use the data obtained in the first step to complete the Subnet mask Gateway and the DNS server addresses The computer will change the IP address a...

Page 18: ...e 1 Guard 2 Never connect different guard types the device could be damaged 2 Aux 2 3 Guard 2 4 Guard 2 5 Aux 2 6 Guard 2 7 NC Not connected 8 Guard 1 9 Aux 1 10 Guard 1 11 Guard 1 12 Out 1 13 Guard 1...

Page 19: ...l with serial number 11 2 Inside Type label with serial number on the left side 12 Order code Type Order Code BatFlex Base Device with Reference Card AA 10320 001 Bat Flex Small Dual 8 Channels AA 103...

Reviews: