MAINTENANCE
Refer to the
Maintenance Schedule
on
Page 61
for maintenance tasks, procedures, frequency, and a listing of by
whom the tasks should be performed. Always verify proper fireplace operation after servicing.
WARNING
Turn OFF gas and electrical power to the fireplace and allow it to cool before cleaning or
servicing the appliance.
CAUTION
Wear gloves and safety glasses for protection while doing required maintenance.
Verify proper operation after servicing.
S’assurer que l’appareil fonctionne adéquatement une fois l’entretien terminé.
Always turn OFF gas before cleaning. Before relighting, refer to the lighting instructions in this manual.
Instructions are also found on a pull-out panel located in the control compartment.
Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids.
Inspecting the venting system
The fireplace and venting system should be thoroughly inspected before initial use and at least annually by a qualified
service technician. Inspection should include ensuring that exhaust or intake passages are unobstructed and vent
components are properly assembled and not damaged.
The homeowner must contact a qualified service technician at once if any abnormal condition is observed.
If the venting system is disassembled for any reason, a qualified service technician should follow vent installation
instructions for proper reassembly and proper sealing of the venting system components. However, more frequent
periodic inspections and cleanings should be performed by the homeowner.
NOTE:
Prior to the first use of the fireplace and each burn season and periodically during the burn season, inspect
the horizontal termination for debris such as bird nests, leaves, paper or branches. Remove any items from
the surfaces of the termination prior to use. Also be aware of shrubs and plantings that may encroach on the
termination.
Inspecting the fireplace lamp
Use the remote control to confirm the fireplace lamp is operational. If the lightbulb is burned out, replace the lightbulb.
Replacing the fireplace lamp lightbulb
1.
Remove the fireplace glass door.
2.
Locate the lamp inside the top, front of the firebox.
3.
Using a 5/16” nut driver, remove the two (2) outside screws securing the lamp glass cover bracket. Carefully,
remove the metal bracket, lamp glass cover, and gasket. Retain all items with the screws in a secure location for
later reinstallation.
4.
Unscrew the lightbulb cap and retain in a secure location for later reinstallation. Unscrew the lightbulb and
discard.
5.
Install the new lightbulb.
6.
Use only 25 W, 572 °F (300 °C) rated oven lightbulbs.
7.
Reinstall the lightbulb cap.
8.
Carefully, position the gasket, lamp glass cover, and metal bracket into place and secure using the two (2)
screws previously removed.
9.
Reinstall the glass door.
Inspecting the burner flame appearance
Periodically inspect the burner and pilot flame. Ensure that the burner flame appearance resembles the flame shown
in
Figure 34 or 35
and as described in
Flame Appearance and Sooting on Page 38
. Any necessary burner flame
adjustments must be performed by qualified personnel only (
Page 37
). Refer to
Page 37
for more information about
the pilot flame appearance. Contact a qualified service technician at once if any abnormal condition is observed.