Installation
900005-00, 10/2015
Innovative Hearth Products
Envy™ Direct-Vent Gas Fireplaces
42
NOTE:
The integrated finish trim is adjustable to accommodate a wall thickness of an additional 1” (25 mm)—for
a 2” (51 mm) total thickness.
NOTE:
For wall thicknesses greater than 2” (51 mm), remove the three integrated finish trim pieces (
Figure 40
).
Figure 41 - Non-combustible Wall
Figure 42 - Wall Finishing
15 1/2
(394)
Shaded area is non-combustible wall
The shaded area
must remain clear of
combustible materials
Combustible
finished wall
materials
Combustible
materials
not allowed
below this
point on the
face of the
appliance
1” (25 mm)
Minimum
Spacer
Top of Appliance
Top of Door Frame
15-1/2”
394 mm
NOTE:
See
Cold Climate Insulation on Page 10
and
Vent Termination Clearances on Page 12
.
5.
Slide the finish trim in until it is flush with the finished wall surface. Tighten the nine (9) screws (
Figure 40
)
securing the finish trim.
6.
Install the surround trim assembly (
Figure 48
).
7.
Slide the left finish trim gap filler into the left gap between the finish trim and the surround trim assembly
(
Figure 47
).
NOTE:
NOTE: Ensure the finish trim gap filler slides into the spring clip, as shown.
8.
Slide the right finish trim gap filler into the right gap between the finish trim and the surround trim assembly
(
Figure 47
).
NOTE:
Ensure the finish trim gap filler slides into the spring clip, as shown.
WARNING
The surround trim assembly includes an integrated barrier to reduce the risk of burns from the
hot viewing glass. Do not operate the fireplace without the surround trim assembly / barrier
installed.
19.
Attach the Safety-in-Operation Warning Labels
1.
Attach the furnished safety instruction labels at all fireplace operation and control points (
Page 43
).
NOTE:
The installer MUST ensure these warnings are properly attached during installation. The warning labels
are a critical means of informing consumers of safe operation practices.