Operation
900921-00E, 06/2019
Innovative Hearth Products
Aries™ -C Series Direct-Vent Gas Fireplaces
59
6.
Install right rear log (4)
(
Figure 44
).
This log should be placed as far to the right as the slot allows.
7.
Install the twig log (5)
(
Figure 45
).
This log rests on the left rear log and the grate.
Installing the Aries™ -C 35 Series Log Set (continued)
Figure 44 - Place right rear log (4)
Figure 45 - Place twig log (5)
Bottom View
Top View
4
Slot fit over Tab
shown in Figure 40
5
8.
Tear the glowing embers into dime size pieces. Place glowing embers as shown in
Figure 46
.
Figure 46 - Place glowing embers (rockwool)
Do NOT place embers on or close to large
ports or the pilot area as seen here (circled).
NOTE:
Enough glowing ember material is provided for several applications.
For best glowing effect, replace the ember material annually.
Top View
Bottom View