– Viron e-Quilibirum Series Chlorinator Instructions V07_14
7
2.3 Connecting the PVC Acid Tube
Before installing the unit in position on the wall or post, the length of the PVC tubing provided should be
measured and taken into consideration. Ensure the controller and cell are close enough for the power
supply lead to reach the cell and sufficient PVC tube exists to connect acid container and cell. To avoid
loss of water from the system, close all stop valves before cutting any lines.
Thread the clear PVC tube through a hole in the cap or shoulder of the chemical container and fit the non-
return or check valve and the weight. Ensure that the non-return valve is fitted correctly. Drop the weight,
with the non-return valve into the bottom of the container.
The clear PVC tube should be snuggly fit in the hole in the cap or shoulder of the chemical container. A
small 2mm breather hole should be made in the cap or shoulder to allow air to fill the void created by the
acid pumped into the pool.
Connect the other end of the PVC tube to the inlet of the acid pump on the front of the controller.
Connect the remaining hose to the outlet of the acid pump on the underside of the controller. The
remaining end of the PVC hose should be pushed through the cable gland iin the 50mm PVC T fitting so
that it passes through the cable gland by 25mm to 30mm.
Locate the Mixing Cell (diagram below) in a horizontal position with the “Locate to Top” embossing in the 12
o’clock position after the Chlorinator cell on the return to pool side. Glue in 50mm PVC pipe into barrel
unions tails or use 50 x 40mm reducers in the barrel union tails if existing plumbing is 40mm high pressure
PVC pipe. Alternatively, locate the mixing cell is a vertical position after the chlorinator cell on the return
side to the swimming pool.
TIP:
Soaking the ends of the PVC tubing in hot water or gentle heating with a lighter makes it easier to
push onto the barb. When installing acid container in a filter enclosure, which has no ventilation, it is
recommended that the hole in the cap of the container is cut or drilled to fit tightly around the tubing, so that
fumes from the acid will not corrode the equipment. It will be necessary to drill a second hole in the cap
fitted tightly with a length of tubing which should then be vented outside the filter enclosure. This procedure
is recommended only where the filter enclosure has no ventilation and is to protect the equipment.
Summary of Contents for Viron eQuilibrium Salt Chlorinator
Page 6: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 6...
Page 14: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 14...
Page 25: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 25...
Page 26: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 26...
Page 27: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 27...
Page 28: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 28...