– Viron e-Quilibirum Series Chlorinator Instructions V07_14 

3.3 Timer Recommendations: 

 

AstralPool recommend that you use two timers, one for the morning and one for the evening and typically for 
periods of 2-5 hours for each. Generally, you should operate your pool for 8 hours a day in total to achieve 
sufficient chlorine production and circulate the pool water including skimming which will reduce debris settling in 
the pool and ongoing maintenance.   Your Viron Series chlorinator is most effective if running in the early morning 
or evening when it is cooler (strong sunlight consumes more chlorine).  As a default, the control is set to come on 
at 08:00 hours and 16:00 hours both for periods of 4 hours.      

 

 
 
 
 

4.0 Operating Functions Accessed through Maintenance Program 

Press 

MAINT  

To backwash your filter press 

BWASH 

and then the up or down arrows to select the backwash time. You can 

press ABORT at any time to finish the back wash. To rinse the filter, you can select 

BWASH

 again and then select 

the time.  Using this feature will ensure your sand filter is backwashed for the correct time. Note:   Ensure pump is 
off when changing the position of the backwash valve on your filter. As a guide, sand filters should be backwashed 
for 2 to 3 minutes, and then rinsed for 1 minute. 

 

Press 

MAINT

 

 

 

 

 
 
 

 

i. 

Dose will allow you to override the time clock and allow the following: 

a.  Sanitise until the first timer tomorrow morning.   This allows for additional circulation of the swimming pool 

water after treatment or cleaning. Can be used to provide a shock dose of chlorine production.  

b.  Manually prime Acid Pump.  This allows for the clear PVC tube to be filled with Acid on initial start up or 

after changing or refilling the Acid Container.  The priming period is for 300 seconds but can be stopped at 
any time.    Should the tube not be completely filled with Acid after 300 seconds repeat the process. 

c.  Manually Dose Acid.  Selecting this function allows you to manually dose acid for a predetermined time.   

Should your pool professional recommend the addition of Acid to your pool, select this function and press 
the up (or down) arrow to select the quantity of acid in litres you wish to dose.   Press ACCEPT.   The 
controller will then ask you what mode you wish the unit to revert to at the completion of Acid dosing, 
“AUTO”, “ON” or “OFF”.   In normal circumstances you will select “AUTO” which puts the unit back into 
time clock operation. 

 
 
 
 

 

POOL SANITISING OFF 

UNIT 16:00 

SET 

  DOSE    NEXT 

 

 

POOL SANITISING OFF 

UNIT 16:00 

SET 

 

         MAINT 

 

 Clock 

Timer 

 Clock 

Timer 

Summary of Contents for Viron eQuilibrium Salt Chlorinator

Page 1: ...2600 Perth 08 9350 2600 Sydney 02 9853 2100 Townsville 07 4750 3100 sales astralpool com au Brisbane 07 3308 5400 Adelaide 08 8152 7600 www astralpool com au Bolero ND Cleaner INSTALLATION AND OPERATI...

Page 2: ...for use on Indoor swimming pools UNLESS the pH and Chlorine sensors have been purchased and installed The Viron e Quilibrium can only be purchased through a professional pool business and MUST be inst...

Page 3: ...utput 12 6 2 Adjusting pH Set Point 13 6 3 Installation of the pH sensor 13 6 4 Installation of the Chlorine Sensor 15 7 0 General Operation Pool Chemistry 16 7 1 Setting the Right Chlorine Output and...

Page 4: ...me of the chlorine The purpose of the Viron eQuilibrium series chlorinators is to significantly reduce the level of daily and weekly maintenance required to keep you pool and spa sparkling clean and h...

Page 5: ...ed on a vertical surface wall If mounted on a post a flat sheet 20mm larger than the controller housing must be used a Mount the wall bracket using the screws provided on a secure wall b Glue mixing c...

Page 6: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 6...

Page 7: ...hose to the outlet of the acid pump on the underside of the controller The remaining end of the PVC hose should be pushed through the cable gland iin the 50mm PVC T fitting so that it passes through t...

Page 8: ...which your filtration pump pH control and chlorine production will operate Timers are set by entering a start time and a RUN time for how long you want to operate To set timers do the following a Pre...

Page 9: ...kwash valve on your filter As a guide sand filters should be backwashed for 2 to 3 minutes and then rinsed for 1 minute Press MAINT i Dose will allow you to override the time clock and allow the follo...

Page 10: ...5 minutes power to the pump outlet will be shut down to prevent your pump running dry f ENABLE LIGHT Your SM series chlorinator has an output to operate a single AstralPool ARC LED light g CELL REVER...

Page 11: ...utes before adjusting calibrating The most accurate way to calibrate is to put the probe in a calibration solution Calibration solution is available via AstralPool as a spare part When the controller...

Page 12: ...rine output should only be used when there is no salt in the water In summer the chlorine should be set between 6 and 8 and you should regularly check your chlorine level in your swimming pool to dete...

Page 13: ...chlorinator cell on return to the pool Once the pH value is set your LCD screen will return to the operating information screen which will cycle through the current status of the chlorinator and the...

Page 14: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 14...

Page 15: ...e Chlorine Sensor uses Oxidisation Reduction Potential readings to determine the chlorine level in your pool or spa water ORP is the most reliable and safest way to determine the level of the sanitise...

Page 16: ...lorine ORP should be turned down Refer to Section 10 1 of this operating manual 7 4 pH Level You should keep you pH level between 7 0 and 7 4 for fibreglass pools and 7 2 to 7 8 for other pools 7 5 To...

Page 17: ...is made of glass please take care for even a hair line crack can cause the sensor to read incorrectly causing malfunction After cleaning the sensors wash with water allow 5 10min to settle and check...

Page 18: ...peration in Ai Mode When Ai Mode is selected the Viron e Quilibrium will operate in the following manner The pump and electrode cell will start at the first time period After the initial 5 minute prim...

Page 19: ...iveness of chlorine and NOT the level of chlorine in the water Relying on ppm can provide a false sense of security and may even lead to use of a pool that is dangerous to swim in When chlorine is add...

Page 20: ...tor will produce more chlorine to reach the set point ORP level than it would otherwise need CyA adds to the TA reading If CyA levels of in excess of 50 ppm are present it is good practice to divide t...

Page 21: ...th the Chlorine Sensor Ongoing use of Trichlor or Dichlor will continue to raise the level of CyA causing a reduction in the activity of the chlorine and may cause your eQ Chlorinator to continue to r...

Page 22: ...timer period Increase chlorine output Backwash filter Get Stabiliser between 30 and 60 ppm Increase salt to 4000ppm Increase water temperature or salt level Chlorinator cuts out on overload reduce sal...

Page 23: ...arts of the Product Parts Warranty Period Control box including PCB s 5 years pro rata 0 payable of invoice total year 1 20 payable of invoice total year 2 40 payable of invoice total year 3 60 payabl...

Page 24: ...ct was used for a purpose other than one it was intended for c the Product was repaired modified or altered by any person other than AstralPool d the Product has not been installed maintained and or o...

Page 25: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 25...

Page 26: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 26...

Page 27: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 27...

Page 28: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 28...

Reviews: