background image

Inst315 

– Viron e-Quilibirum Series Chlorinator Instructions V07_14 

3.0   Starting your Chlorinator 

Your Chlorinator Controller operation can be divided into 4 areas; 

 

a.  MAINTENANCE 

– selects specialised functions of your chlorinator and initial set up of Chlorinator to suit 

your pool and spa. 

b.  SET 

– selects changes in Chlorine Product and pH of your pool and spa water 

c.  CLOCK & TIMER buttons 

– sets current time and filtration, chlorine production and pH monitoring and 

adjustment times from Monday to Friday and Weekends 

d.  Pool and Spa Mode 

– Allows selection of pool mode where controller will produce chlorine suitable for pool 

and Spa Mode, where chlorine production and acid dosing is reduced to suit a smaller volume of water in 
the Spa. 

 

3.1   Set up 

 

a. 

Press “

Pool Mode

” button until 

Manually Off

 

appears and then Press “

Clock

” Button 

b. 

Select “

Day

” and use buttons adjacent to LCD screen to set the current day, hour and minute.   The clock 

is a 24 hour clock. 

 

 
 
 
 
 
 
 
 

 

3.2 Setting Timers 

 

Your Viron chlorinator has 4 timers per day enabling you to set different periods in which your filtration pump, pH 
control and chlorine production will operate.  Timers are set by entering a start time, and a 

RUN

 time for how long 

you want to operate. To set timers, do the following: 

 

a.  Press the 

TIMER

 button. 

b.  Press 

HOUR

 button to set the hour for the timer selected and use the Up/Down arrows to change the time.   

c.  Press 

MIN

 button to select the minutes for the timer selected and use the Up/Down arrows to change the 

time.  Press the 

NEXT

 button to select the 

RUN

 time or another time and set as required.   Note:  The 

RUN time represents the number of hours you want the unit to operate for. 

d.  When finished, press the 

NEXT

 button a number of times to scroll through the other times until you return 

to normal display.  This saves your new settings. 

e.  Select 

Auto Sanitising 

by pressing the 

POOL

 mode button.   The 

POOL 

mode button has three settings, 

manually 

ON 

which turns on system indefinitely, manually 

OFF 

which turns system off indefinitely, and 

AUTO 

model which sets the controller on timer clock mode.  In 

AUTO 

mode the LCD screen will display 

the date and pool sanitiser message. 

 
 

 

TIME:  11:07 

 
 HOUR                    MIN 

 

 Clock 

Up & down buttons 

  

Timer 

Select hour and use up or down buttons to change hour.   Select Min and use up or 
down buttons to change the minute 

Summary of Contents for Viron eQuilibrium Salt Chlorinator

Page 1: ...2600 Perth 08 9350 2600 Sydney 02 9853 2100 Townsville 07 4750 3100 sales astralpool com au Brisbane 07 3308 5400 Adelaide 08 8152 7600 www astralpool com au Bolero ND Cleaner INSTALLATION AND OPERATI...

Page 2: ...for use on Indoor swimming pools UNLESS the pH and Chlorine sensors have been purchased and installed The Viron e Quilibrium can only be purchased through a professional pool business and MUST be inst...

Page 3: ...utput 12 6 2 Adjusting pH Set Point 13 6 3 Installation of the pH sensor 13 6 4 Installation of the Chlorine Sensor 15 7 0 General Operation Pool Chemistry 16 7 1 Setting the Right Chlorine Output and...

Page 4: ...me of the chlorine The purpose of the Viron eQuilibrium series chlorinators is to significantly reduce the level of daily and weekly maintenance required to keep you pool and spa sparkling clean and h...

Page 5: ...ed on a vertical surface wall If mounted on a post a flat sheet 20mm larger than the controller housing must be used a Mount the wall bracket using the screws provided on a secure wall b Glue mixing c...

Page 6: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 6...

Page 7: ...hose to the outlet of the acid pump on the underside of the controller The remaining end of the PVC hose should be pushed through the cable gland iin the 50mm PVC T fitting so that it passes through t...

Page 8: ...which your filtration pump pH control and chlorine production will operate Timers are set by entering a start time and a RUN time for how long you want to operate To set timers do the following a Pre...

Page 9: ...kwash valve on your filter As a guide sand filters should be backwashed for 2 to 3 minutes and then rinsed for 1 minute Press MAINT i Dose will allow you to override the time clock and allow the follo...

Page 10: ...5 minutes power to the pump outlet will be shut down to prevent your pump running dry f ENABLE LIGHT Your SM series chlorinator has an output to operate a single AstralPool ARC LED light g CELL REVER...

Page 11: ...utes before adjusting calibrating The most accurate way to calibrate is to put the probe in a calibration solution Calibration solution is available via AstralPool as a spare part When the controller...

Page 12: ...rine output should only be used when there is no salt in the water In summer the chlorine should be set between 6 and 8 and you should regularly check your chlorine level in your swimming pool to dete...

Page 13: ...chlorinator cell on return to the pool Once the pH value is set your LCD screen will return to the operating information screen which will cycle through the current status of the chlorinator and the...

Page 14: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 14...

Page 15: ...e Chlorine Sensor uses Oxidisation Reduction Potential readings to determine the chlorine level in your pool or spa water ORP is the most reliable and safest way to determine the level of the sanitise...

Page 16: ...lorine ORP should be turned down Refer to Section 10 1 of this operating manual 7 4 pH Level You should keep you pH level between 7 0 and 7 4 for fibreglass pools and 7 2 to 7 8 for other pools 7 5 To...

Page 17: ...is made of glass please take care for even a hair line crack can cause the sensor to read incorrectly causing malfunction After cleaning the sensors wash with water allow 5 10min to settle and check...

Page 18: ...peration in Ai Mode When Ai Mode is selected the Viron e Quilibrium will operate in the following manner The pump and electrode cell will start at the first time period After the initial 5 minute prim...

Page 19: ...iveness of chlorine and NOT the level of chlorine in the water Relying on ppm can provide a false sense of security and may even lead to use of a pool that is dangerous to swim in When chlorine is add...

Page 20: ...tor will produce more chlorine to reach the set point ORP level than it would otherwise need CyA adds to the TA reading If CyA levels of in excess of 50 ppm are present it is good practice to divide t...

Page 21: ...th the Chlorine Sensor Ongoing use of Trichlor or Dichlor will continue to raise the level of CyA causing a reduction in the activity of the chlorine and may cause your eQ Chlorinator to continue to r...

Page 22: ...timer period Increase chlorine output Backwash filter Get Stabiliser between 30 and 60 ppm Increase salt to 4000ppm Increase water temperature or salt level Chlorinator cuts out on overload reduce sal...

Page 23: ...arts of the Product Parts Warranty Period Control box including PCB s 5 years pro rata 0 payable of invoice total year 1 20 payable of invoice total year 2 40 payable of invoice total year 3 60 payabl...

Page 24: ...ct was used for a purpose other than one it was intended for c the Product was repaired modified or altered by any person other than AstralPool d the Product has not been installed maintained and or o...

Page 25: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 25...

Page 26: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 26...

Page 27: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 27...

Page 28: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 28...

Reviews: