![Astralpool PRO ELYO INVERBOOST NN User And Service Manual Download Page 9](http://html1.mh-extra.com/html/astralpool/pro-elyo-inverboost-nn/pro-elyo-inverboost-nn_user-and-service-manual_2990573009.webp)
- 16 -
Technical data PRO ELYO INVERBOOST NN pool heat pumps
CE Standard, R32, ABS Cabinet
MODEL
PROELYXP16i
PROELYXP20i
PROELYXP26i
PROELYXP30i
CODE
71680
71681
71682
71683
* Performance at Air 28
℃
, Water 28
℃
, Humidity 80%
Heating capacity
Kw
16-3.8
20-4.7
26-5.9
30-6.8
Power consumption
Kw
2.39-0.24
2.99-0.29
3.88-0.37
4.55-0.43
C.O.P.
16-6.7
16-6.7
16-6.7
16-6.6
* Performance at Air 15
℃
, Water 26
℃
, Humidity 70%
Heating capacity
Kw
11.2-3
14-3.9
18-5.4
22.8-5.6
Power consumption
Kw
2.24-0.38
2.8-0.49
3.6-0.68
4.56-0.68
C.O.P.
8.2-5
8.2-5
8.2-5
8.2-5
* Performance at Air 0
℃
, Water 26
℃
, Humidity 78%
Heating capacity
Kw
7.4-4.1
9.79-4.8
13-6.7
15.89-8.5
Power consumption
Kw
2.64-0.91
3.5-1.09
4.64-1.52
5.68-1.93
C.O.P.
4.5-2.8
4.4-2.8
4.4-2.8
4.4-2.8
* Performance at Air -10
℃
, Water 26
℃
, Humidity 78%
Heating capacity
Kw
5.8-3.6
7.58-4.3
10.4-5.9
12.74-7.4
Power consumption
Kw
2.64-0.92
3.45-1.1
4.73-1.51
5.79-1.95
C.O.P.
3.9-2.2
3.9-2.2
3.9-2.2
3.8-2.2
* General data
Compressor type
MITSUBISHI INVERTER COMPRESSOR
Voltage
V
220V-240V/50Hz or 60Hz/1PH
Rated current
A
10.5
13.2
17.0
23.0
Minimum fuse
A
16
20
26
35
Advised pool volume
m³
28-85
58-120
65-132
78-156
Advised water flux
m
3
/h
5.0
6.0
8.0
10.0
Water pressure drop
Kpa
15
18
20
25
Heat exchanger
Twist-titanium tube in PVC
Water connection
mm
50
No. of Fan
1
Ventilation type
Horizontal
Fan speed
RPM
450-650
(550-850)*2
Power input of Fan
W
35-130
(32-110)*2
Noise level(10m)
dB(A)
≤ 43
≤ 45
≤ 49
≤ 49
Noise level(1m)
dB(A)
40-54
41-56
42-60
42-60
Refrigerant (R32)
g
1500
1900
2000
2600
CO2 equivalent
Tonne
1.01
1.28
1.35
1.76
* Dimension/ Weight
Net weight
kg
98
117
128
130
Gross weight
kg
113
135
146
148
Net dimension
mm
1050*450*870
1050*452*1295
Packing dimension
mm
1140*480*1010
1130*515*1430
3.
3.
3.
Specifications
Specifications
Specifications
Summary of Contents for PRO ELYO INVERBOOST NN
Page 2: ...9 SWIMMING POOL HEAT PUMP PRO ELYO INVERBOOST NN User and Service manual...
Page 5: ...12 Models 71677 71678 71679 Models 71680 71681 1 1 1 Description Description Description...
Page 6: ...13 Models 71682 71683 68821 68822 68823 1 1 1 Description Description Description...
Page 41: ...48 9 1 Exploded Diagram Mode 71676 9 9 9 Exploded Exploded Exploded Diagram Diagram Diagram...
Page 43: ...50 9 3 Model 71677 71678 71679 9 9 9 Exploded Exploded Exploded Diagram Diagram Diagram...
Page 47: ...54 9 7 Model 71680 71681 9 9 9 Exploded Exploded Exploded Diagram Diagram Diagram...
Page 50: ...57 9 10 Model 71682 71683 9 9 9 Exploded Exploded Exploded Diagram Diagram Diagram...
Page 53: ...60 9 13 Model 68821 68822 68823 9 9 9 Exploded Exploded Exploded Diagram Diagram Diagram...