![Astralpool PRO ELYO INVERBOOST NN User And Service Manual Download Page 40](http://html1.mh-extra.com/html/astralpool/pro-elyo-inverboost-nn/pro-elyo-inverboost-nn_user-and-service-manual_2990573040.webp)
- 47 -
8.2 Other Malfunctions and Solutions (No display on LED wire controller)
Malfunctions
Observing
Reasons
Solution
Heat pump is
not running
LED wire controller
no display.
No power supply
Check cable and circuit breaker if it is
connected
LED wire controller.
Displays the actual time.
Heat pump under standby
status
Startup heat pump to run.
LED wire controller
displays the actual
water temperature.
1. Water temperature is
reaching to setting value, HP
under constant temperature
status.
2. Heat pump just starts to
run.
3. Under defrosting.
1. Verify water temperature setting.
2. Startup heat pump after a few
minutes.
3. LED wire controller should display
"Defrosting".
Water temperature is
cooling when HP runs
under heating mode
LED wire controller displays
actual water temperature and no
error code displays.
1. Choose the wrong mode.
2. Figures show defects.
3. Controller defect.
1. Adjust the mode to proper running
2. Replace the defect LED wire
controller, and then check the status
after changing the running mode,
verifying the water inlet and outlet
temperature.
3. Replace or repair the heat pump
unit
Short running
LED displays actual water
temperature, no error code
displays.
1. Fan NO running.
2. Air ventilation is not
enough.
3. Refrigerant is not enough.
1. Check the cable connections
between the motor and fan, if
necessary, it should be replaced.
2. Check the location of heat pump
unit, and eliminate all obstacles to
make good air ventilation.
3 Replace or repair the heat pump
unit.
Water stains
Water stains on heat pump unit.
1. Concreting.
2. Water leakage.
1. No action.
2. Check the titanium heat exchanger
carefully if it is any defect.
Too much ice on
evaporator
Too much ice on evaporator.
1. Check the location of heat pump
unit, and eliminate all obstacles to
make good air ventilation.
2. Replace or repair the heat pump
unit.
8.
8.
8.
Troubleshooting
Troubleshooting
Troubleshooting
Summary of Contents for PRO ELYO INVERBOOST NN
Page 2: ...9 SWIMMING POOL HEAT PUMP PRO ELYO INVERBOOST NN User and Service manual...
Page 5: ...12 Models 71677 71678 71679 Models 71680 71681 1 1 1 Description Description Description...
Page 6: ...13 Models 71682 71683 68821 68822 68823 1 1 1 Description Description Description...
Page 41: ...48 9 1 Exploded Diagram Mode 71676 9 9 9 Exploded Exploded Exploded Diagram Diagram Diagram...
Page 43: ...50 9 3 Model 71677 71678 71679 9 9 9 Exploded Exploded Exploded Diagram Diagram Diagram...
Page 47: ...54 9 7 Model 71680 71681 9 9 9 Exploded Exploded Exploded Diagram Diagram Diagram...
Page 50: ...57 9 10 Model 71682 71683 9 9 9 Exploded Exploded Exploded Diagram Diagram Diagram...
Page 53: ...60 9 13 Model 68821 68822 68823 9 9 9 Exploded Exploded Exploded Diagram Diagram Diagram...