Fountain units
18
Installation, operation and maintenance manual; Fire Jet
[en]
Component
Number
Anchor bolt: M8 A4 AISI 316 threaded
rod and capsule
6
DIN 9021 D.8 A4 flat washer
6
DIN 934 M8 A4 nut
12
WARNING
:
Risk of damage to the unit.
Install device’s anchoring
following this instructions:
7)
Fasten the anchor bolts (
②
②
②
②
b
) to the ground.
8)
Level the unit and fasten on each anchoring point using 2 nuts
on each in order to prevent from undesired movements
9)
Periodically check the fixing to ensure the equipment vertical
position, to avoid the risks derived from bad equipment
orientation.
2.2
WIRING
2.2.1
Fuel
WARNING
:
Risk of damage to the unit and losing its warranty.
Clean all
piping prior to connecting and starting the unit up.
WARNING
:
Risk of damage to the unit and losing its warranty.
The fuel
impulsion system (isopropanol) made by compressed air, is not
included on the device. It is highly recommendable to install air
regulators and accumulators, necessaries for the correct use of the
device. It is also recommended the installation of an air-drying
system to remove any water in the unit. All this components must be
sized and installed following the current applicable regulations in the
country of installation.
WARNING
:
Risk of damage to the unit and losing its warranty.
Before
the equipment commissioning, carry out tightness testing of the
isopropanol impulsion system from the tank to the equipment. The
manufacturer DOES NOT HAVE ANY RESPONSIBILITY in the
combustible fluid distribution and impulsion installation, but it is
recommended to pay special attention at this point, and
Summary of Contents for AISI316