Fountain units
22
Installation, operation and maintenance manual; Fire Jet
[en]
4
TECHNICAL SPECIFICATIONS
Input voltage
230 V AC
Total power load
500 W
Rated current
2.7 A.
Maximum pressure
16 bar
Jet nozzle height
4–10 m
Isopropanol consumption
0,2 l/s
5
FAQS
Question
Answer
Why isn’t the isopropanol
discharged from the nozzle?
If you have an anemometer
sensor, the wind speed may be
faster than the default set-point.
Wait until the wind speed in the
area has dropped.
Check that the control panel’s
electrical outlet is on.
Check the status of the circuit
breaker.
Why doesn’t the isopropanol
discharged from the nozzle
ignite?
Check the position of the
electrodes. The electric arc
between the electrodes may
not be forming.
Check that the control panel’s
electrical outlet is on.
In other cases or if the answers have not resolved the problem
detected, contact a service engineer (see the list of approved
engineers on the product’s warranty).