Fountain units
Installation, operation and maintenance manual; Fire Jet
15
[en]
1
GENERAL SAFETY
1.1
ELECTRICAL SAFETY
-
Disconnect the unit from the power supply before doing any
assembly or maintenance jobs.
-
Do not touch the water or get into the water while the unit is
connected to the power supply.
-
Use an H07RN-F type waterproof cable.
-
Connect the unit to an earth connection. Make use of one of the
unit’s fastening points (see chapter 2.1).
-
It is mandatory to install a security system in the electrical panel to
monitor the electric arc activation by current. Only in this case the
isopropanol solenoid valves can be activated. As it is a safety
system, the non-installation, deactivation or lack of maintenance
exempts the manufacturer from liability for damage to persons,
installations and equipment operation.
-
It is mandatory to install an emergency stop system that cut the
power supply to the equipment, in case of risks derived from
equipment malfunction.
-
Connect the unit to a power supply with an earth connection,
protected by the following components:
•
An RCD safety switch with a maximum residual current of 30
mA.
•
A circuit breaker fuse properly sized according to the power
consumption of the unit.