If the distance between the machine and the outside air is too high, a duct can be connected
directly to the evaporator inlet, as long as the nominal air flow of the equipment is
guaranteed. The limit of loss of load of these models Indoor is 120 Pa, and if this value is not
respected, the heat pump can be damaged. For greater load losses available, consult Fluidra
Comercial.
5.4
CONDENSATION DRAIN
The MAYA / OPTIMA will naturally generate condensation water. This water will be gathered
inside the machine and will come out through a condensation drain located on the frame of
the equipment. The installation must have a drain to evacuate such condensation water.
The condensation drain is identified by this decal on the machine:
It is advised to install a siphon in the condensation drainage to prevent liquid and odours
returns.