5
INSTALLATION
All the diagrams in this manual show the installation of the GSM Remote Control Unit, model
MGR100G REFERENCE.
Note:
The main DC power supply has to be switched off before installation.
Also refer to the instruction manual of the equipment to be connected.
The total power consumption of all sensors, relays and other devices supplied from the
unit has not exceed 500mA.
The MGR100 series remote control unit have to be installed near the control board. Avoid the
installation in engine room, extremely hot places and near appliances generating strong magnetic
fields. The installation have to be realize by a qualified personel.
Note:
The GSM and GPS antennas have to be connected before the unit is switched-on.
The SIM card have to be inserted before the unit is switched-on. The SIM location 3
(password) has to be empty. The PIN code request have to be disabled.
DC power supply and Accumulator connection
The power supply have to be connected to the DC terminal block connector with right polarity and
protected with a fuse (not included). The power supply voltage have to be from 12 - 30VDC. The
back-up accumulator have to be connected to the ACCU terminal block connector with right polarity
and also protected with a fuse (not included).
Note:
The declared accumulator voltage have to be the same as the DC power supply voltage.
F0.5A
F0.5A