ASTEL MGR100 Operating Instructions Manual Download Page 1

MGR100 

 

 GSM 
 REMOTE 
 CONTROL 
 UNIT 

 

 
 

 Operating 

Instructions 

 

 

 

 

 

Summary of Contents for MGR100

Page 1: ...MGR100 GSM REMOTE CONTROL UNIT Operating Instructions ...

Page 2: ... and Microphone connection 8 Remote keyboard connection 8 I2C bus connection 9 RS 232 connection 9 Instructions 10 Login 10 Controls 10 Relays 10 Digital outputs 11 Alarms 12 Digital inputs 12 Analog inputs 13 Temperature sensors 14 GPS receiver 15 Other alarm functions 17 Alarm set up 19 Other functions 19 DTMF instructions 21 SIM card locations 22 Technical Specifications 24 Optional Accessories...

Page 3: ... and microphone connection to remote communication Programming is possible by the help of SMS text messages or with PC by the help of RS 232 serial interface This GSM Remote Control Unit comes in three versions Basic Advance and Reference every model is available also with GPS receiver FEATURES built in GSM module with SIM interface built in GPS module for position management and alarming SMS cont...

Page 4: ...ks in normal operation 7 Alarm LED LED to show the alarm status lights when alarm occurs 8 GSM antenna connector SMA connector to connect GSM antenna 9 RS 232 Terminal block to connect RS 232 control equipment 10 SP MIC Terminal block to connect Speaker and Microphone 11 REMOTE Terminal block to connect external keyboard 12 ANALOG IN Terminal block to connect 4 different voltage sources 13 I2C Ter...

Page 5: ...fields The installation have to be realize by a qualified personel Note The GSM and GPS antennas have to be connected before the unit is switched on The SIM card have to be inserted before the unit is switched on The SIM location 3 password has to be empty The PIN code request have to be disabled DC power supply and Accumulator connection The power supply have to be connected to the DC terminal bl...

Page 6: ...total DC curent consumption of connected equipment to each relay must not exceed 1A when the equipment are controlled directly from the unit The maximum voltage connected to the relays must not exceed 30V Digital outputs connection The digital outputs are suitable to control four different yacht electrical and electronic devices connected through external relays Note The total DC curent consumptio...

Page 7: ...the unit and connected to one of ACCU terminal block Note The total power consumption of each sensor supplied from the unit must not exceed 100mA Analog inputs connection The analog inputs are suitable to connect four different voltage sources like are boat accumulators and to measure their voltages Note Only the DC voltage can be connected to the analog inputs The maximum DC voltage connected to ...

Page 8: ...s Speaker and Microphone connection The unit is designed to connect the microphone which enables to listen the voice and low power speaker for communication and notification Note Only the specified speaker and microphone can be connected to the unit Remote keyboard connection The unit is designed to connect the simple remote keyboard which enables operating with the unit to enable and disable the ...

Page 9: ...sing I2C protocol can be connected to the I2C interface RS 232 connection The unit is designed to connect also the devices using the RS 232 serial interface control like personal computer or other devices Note Only the devices using RS 232 serial interface can be connected to the RS 232 port KEYBOARD I2C bus device PC ...

Page 10: ...ions To change the password NPWxxxx x 1 9 NPW2222 if the new password is 2222 Controls Relays To receive a status of relays REL Received SMS NAME REL1 REL1 12 10 00 REL2 REL2 ON REL3 REL3 OFF REL4 REL4 REM To switch on the relay RELxON x 1 4 REL1ON to switch on the relay 1 To switch off the relay RELxOFF x 1 4 REL1OFF to switch off the relay 1 To switch on the relay for selected time duration RELx...

Page 11: ... on audio or other indication on the relay 4 Digital outputs To receive a status of open collector outputs OCE Received SMS NAME OCE1 OCE1 12 10 00 OCE2 OCE2 ON OCE3 OCE3 OFF OCE4 OCE4 REM To switch on the open collector output OCExON x 1 4 OCE1ON to switch on the open collector output 1 To switch off the open collector output OCExOFF x 1 4 OCE1OFF to switch off the open collector output 1 To swit...

Page 12: ...3 ON D4 IN4 OFF D5 IN5 OFF D6 IN6 OFF D7 IN7 REM D8 IN8 REM when switching on off of alarming is enabled by the help of the digital inputs D7 in D8 To enable alarms on digital inputs ADSxxxxxxxx x 1 or 0 ADS00100000 to enable alarm on digital input 3 To receive alarm triggering on digital inputs ADT Received SMS NAME TRG D1 HIGH D2 HIGH D3 LOW D4 LOW D5 LOW D6 LOW D7 REM D8 REM when switching on o...

Page 13: ... ALARM IN3 LOW Analog inputs To receive alarm status on analog inputs AAS Received SMS NAME ALM A1 V1 OFF A2 V2 OFF A3 V3 OFF A4 V4 ON A5 DC ON A6 ACCU ON To enable alarms on analog inputs AASxxxxxx x 1 or 0 AAS000111 to enable alarm on analog input 4 5 6 To receive alarm triggering on analog inputs AAT Received SMS NAME TRG A1 Low 10 2V High 20 2V A2 Low 0 0V High 30 0V A3 Low 0 0V High 30 0V A4 ...

Page 14: ...ceived SMS NAME ALARM V4 10 5V ALARM DC 9 5V ALARM ACCU 9 5V Temperature sensors To receive alarm status on temperature sensors ATS Received SMS NAME ALM T1 TEMP1 OFF T2 TEMP2 OFF T3 TEMP3 ON To enable alarms on temperature sensors ATSxxx x 1 3 ATS001 to enable alarm on sensor 3 To receive alarm triggering on temperature sensors ATT Received SMS NAME TRG T1 Low 20 0C High 30 0C T2 Low 50 0C High 1...

Page 15: ... 5C Alarming Received SMS NAME ALARM TEMP3 38 5C GPS receiver To receive alarm status on pre defined positions AGS Received SMS NAME ALM P1 POS1 ON P2 POS2 OFF P3 POS3 OFF P4 POS4 ON To enable alarms on pre defined positions AGSxxxx x 1 or 0 AGS1001 to enable GPS alarm on position 1 and 4 To receive alarm triggering on pre defined positions AGT Received SMS NAME TRG P1 Out 0 25km P2 In 0 20km P3 I...

Page 16: ...re defined positions for alarm triggering AGC Received SMS NAME POS P1 Lat 45 45 281N Lon 013 49 892E P2 Lat 0 Lon 0 P3 Lat 0 Lon 0 P4 Lat 45 48 390N Lon 013 48 300E To define positions for alarm triggering AGCxann nn nnnbnnn nn nnn x 1 4 a n s b e w n 1 9 AGC1n45 45 281e013 49 892 position 1 is 45 45 281N in 013 49 892E To avtomatically insert the alarm position by the help of momentary position ...

Page 17: ... seconds when the alarming is switched on off by the remote control the delay time remains the same To enable the switching on off of alarming by the remote control on the inputs KEY1 and KEY2 REMKON REMKON switching on off of alarming is enabled To enable the switching on off of alarming by the remote control on the inputs D7and D8 REMDON REMDON switching on off of alarming is enabled To disable ...

Page 18: ...in D8 To receive alarm status ALM Received SMS NAME ALARMS ON the alarming is switched on Received SMS NAME ALARMS ON DEL 00 02 30 the alarming is switched on with delay of 2 minutes and 30 seconds To check alarmed functions ALMCHK Received SMS NAME ALARM IN7 LOW Received SMS NAME ALARM V4 10 5V Received SMS NAME ALARM DC 9 5V Received SMS NAME ALARM ACCU 9 5V Received SMS NAME ALARM TEMP3 38 5C R...

Page 19: ... and on the models with GPS receiver also by the AGS AGT AGC or AGMx When the remote control is used set the switching on off of alarming by instructions REMKON or REMDON and audio or other indication by instructions RELxREM or OCExREM When the relays are used with alarming set the relay time by instruction RELxALM Switch on the alarming by instructions ALMON or ALMONhh mm ss or with remote contro...

Page 20: ...rel to send the relay status on GSM tel number 0038641123456 To write the number to the location on the SIM card PBWs x s location on the SIM card x number PBW55 0038641123456 to write the number 0038641123456 on the location 55 To write the name to the location on the SIM card PBWs n s location on the SIM card n name PBW55 kiko to write the name KIKO on the location 55 To write the name and numbe...

Page 21: ...4 password 81x to switch on the relays 80x to switch off the relays 71x to switch on open collector outputs 70x to switch off open collector outputs 98 to generally enable all alarms 97 to generally disable all alarms 60 to check alarmed functions 95 to switch on a microphone 96 to switch on a microphone and speaker 91 to receive the status like SMS instruction ...

Page 22: ...MS number 0 no SMS 9 location of the last SMS number 10 reserved 11 IN1 12 IN2 13 IN3 14 IN4 15 IN5 16 IN6 17 IN7 18 IN8 19 REL1 20 REL2 21 REL3 22 REL4 23 OC1 24 OC2 25 OC3 26 OC4 27 TEMP1 28 TEMP2 29 TEMP3 30 NAME 31 reserved 32 reserved 33 reserved 34 reserved 35 reserved 36 V1 37 V2 38 V3 39 V4 40 ACCU 41 DC 42 reserved 43 SMS number 1 44 SMS number 2 45 SMS number 3 46 SMS number 4 47 SMS num...

Page 23: ...served 55 POS1 56 reserved 57 POS2 58 reserved 59 POS3 60 reserved 61 POS4 reserved 90 call number 1 91 call number 2 92 call number 3 93 call number 4 94 call number 5 95 call number 6 96 call number 7 97 call number 8 98 call number 9 99 call number 10 ...

Page 24: ...e GPS receiver 12 parallel channel GPS receiver 1 second update rate Accuracy position 15m 95 typical 100m with selective availability on Sensitivity 165 dBW min Antenna connector SMA only for ADVANCE and REFERENCE models only for REFERENCE model only for MGR100G models with GPS receiver OPTIONAL ACCESSORIES Temperature sensor MT 01 Temperature sensor MT 02 IR intruder sensor MIR 01 IR intruder se...

Page 25: ...the Purchaser at the Warrantor s expense d no refund of the purchase price will be granted to the Purchaser unless the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so Prior to refund of the purchase price Purchaser must submit a statement in writing from a professional boating equipment supplier that the installation instructions of the Operating...

Page 26: ...ote Control Unit MGR100 series conform to the following Product Specifications Radio Spectrum EN 300 511 and 3GPP 51 010 1 EMC EN 301 489 1 and EN 301 489 7 Electrical Safety EN 60950 Supplementary Information The products herewith comply with the requirements of the following Directives and carry the CE marking accordingly the R TTE Directive 1999 5 EC the Low Voltage Directive 73 23 EEC the EMC ...

Page 27: ...t MGR100G series conform to the following Product Specifications Radio Spectrum EN 300 511 and 3GPP 51 010 1 EMC EN 301 489 1 and EN 301 489 7 EN 50082 1 and EN 61000 6 1 Electrical Safety EN 60950 Supplementary Information The products herewith comply with the requirements of the following Directives and carry the CE marking accordingly the R TTE Directive 1999 5 EC the Low Voltage Directive 73 2...

Page 28: ...ASTEL d o o Dutovlje 138 6221 Dutovlje Slovenia Tel 386 5 7310771 386 5 7310772 Fax 386 5 7310789 E mail info astel marine com Web www astel marine com ...

Reviews: