7
E A S Y S T S
I N S T R U C T I O N S H E E T
Control and motor system:
Oelschläger Metalltechnik GmbH
Adjustment mechanism:
Spindle adjustment in the leg
Synchronization:
electr. synch. by electr. control unit
Tube diameter of the lift columns: 90 mm / 85 mm / 80 mm (outside / middle / inside)
Temperature range at point of use: + 5°C to + 40°C
Max. relative humidity:
80 %
Rated voltage:
Input: AC 100-240 V ~
Rated frequency:
50 Hz
Intermittent periodic duty:
max. 2 min / 18 min
Maximum load:
Desk:
80 kg
CPU
holder:
15
kg
Equipment
holder: 15
kg
Protection class:
IP 20
Maximum power consumption
during lifting operation:
2 lift columns 450 W
Power consumption in
standby mode:
< 0.3 W
Traversing speed:
38 mm/s (without load)
Maximum adjustment range:
600 mm
Control panel up / down:
Standard
Operating panel with
memory function:
Optional (wired)
Noise emission:
< 50 dB(A)
Rating plates are located on the control system housing,
the lift columns and underneath the desktop.
Technical data