background image

3.3

Electronic equipment reception interference

The equipment may generate and use radio frequency energy and if not installed and used properly,
it may cause interference to radio, television reception or other radio frequency type systems.

If other equipment does not fully comply with immunity requirements, interference may occur.

There is no guarantee that interference will not occur in a particular installation. If this equipment
does cause interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:

• Re-orient the receiving antenna.

• Relocate the receiver with respect to the equipment.

• Move the receiver away from the equipment.

• Plug the receiver into a different outlet so that equipment and receiver are on different branch

circuits.

• Check that protective earth (PE) is connected.

If necessary, the user should consult the dealer or an experienced electronics technician for addi-
tional suggestions.

3.4

Environmental requirements

ASSA ABLOY Entrance Systems products are equipped with electronics and may also be equipped
with batteries containing materials which are hazardous to the environment. Disconnect power
before removing electronics and battery and make sure it is disposed of properly according to local
regulations (how and where) as was done with the packaging material.

1020004-en-US-2.0

Issue 2020-10-27

8

3 Important information

Summary of Contents for SW60

Page 1: ...Original instructions Installation and Service Manual Swing Door Operator ASSA ABLOY SW60 Entrance Systems...

Page 2: ...are trademarks owned by the ASSA ABLOY Group ASSA ABLOY Entrance Systems 2020 Technical data subject to change without notice Backtrack information folder Workspace Main version a610 Date 2020 09 02...

Page 3: ...SE impulse 12 5 2 12 Power assist 12 5 2 13 Push and go 12 5 2 14 Function of locks 12 5 2 15 Impulses 12 5 2 16 Statistics 12 5 2 17 Factory reset 13 6 Part identification 15 7 Arm systems 15 7 1 Pus...

Page 4: ...Remove user 43 12 2 8 Log in to the app with user 44 12 2 9 Configuration parameters 45 13 Cover 46 14 Troubleshooting 47 15 Service Maintenance 48 16 ANSI BHMA A156 19 LOW ENERGY APPLICATION 48 16 1...

Page 5: ...1 Revision Following pages have been revised Revision 1 0 2 0 Page Updated screenshots for the app 5 Issue 2020 10 27 1020004 en US 2 0 1 Revision...

Page 6: ...ed by a person responsible for their safety Theoperatorcanbeusedbypersonswithimpairedphysical sensory ormentalcapacityiftheyhavebeeninstructedbyapersonincharge of their safety Cleaning and user mainte...

Page 7: ...manual contains the necessary details and instructions for the installation maintenance and service of the Swing Door Operators ASSA ABLOY SW60 Make sure that the connection to the source of supply b...

Page 8: ...asures Re orient the receiving antenna Relocate the receiver with respect to the equipment Move the receiver away from the equipment Plug the receiver into a different outlet so that equipment and rec...

Page 9: ...ces and speeds as related to door weight and width 30 48 Door width Selectable 12 V DC max 1200 mA or 24 V DC max 600 mA Electro mechanical locking device PUSH arm 80 110 with reveal 0 5 1 8 Door open...

Page 10: ...ly 4 1 Permitted door weight and door width Permitted door weight and door width Push arm 150 Lbs 48 or 266 Lbs 36 Pull arm 112 Lbs 48 or 200 Lbs 36 Note Complies with UL 325 1020004 en US 2 0 Issue 2...

Page 11: ...2 2 Exit Passage from inside only The door is normally locked if an electromechanical locking device has been fitted The door can only be opened with the inner wall or jamb mounted contact switches i...

Page 12: ...ntil a new impulse is given OPEN CLOSE impulse works only in program selection AUTO and EXIT 5 2 12 Power assist The motor will give increase power assist when the door is opened manually If the param...

Page 13: ...6 Part identification 13 Issue 2020 10 27 1020004 en US 2 0 6 Part identification...

Page 14: ...aptor holder 331020253 10 Extension power cable 331704236 11 Cover Black 331020809DB 12 Cover Silver 331020809NA Power cord 331018859 13 Power adaptor 331703711 14 Power box adaptor kit 331020293 15 P...

Page 15: ...7 1 Pushing installation with PUSH arm Reveal 0 2 11 16 0 68mm Art No 1020224 2 1 4 5 1 8 56 130mm Art No 1019456 7 1 1 Drive shaft extension kits for PUSH arm 15 Issue 2020 10 27 1020004 en US 2 0 7...

Page 16: ...7 2 Pulling installation with PULL arm Art No 1020226 7 2 1 Drive shaft extension kits for PULL arm 1020004 en US 2 0 Issue 2020 10 27 16 7 Arm systems...

Page 17: ...ompliance centerofpushplate s mustbe34 48 abovefinishedfloororheightrequired by local AHJ 8 1 1 Push plates 8 1 2 Remote transmitter push plates 8 1 3 Installation box for narrow plates 17 Issue 2020...

Page 18: ...ide Operator designed for disabled people Dual Side AUTOMATIC DOOR CAUTION Pull side PULL TO ACTIVATE Push side PUSH TO ACTIVATE AAADM safety Dual Side Activate Switch to Operate Product labels 102000...

Page 19: ...in good mechanical condition Ensure proper material is being used for the door leaves and that there are no sharp edges Projecting parts shall not create any potential hazards If glass is used bare gl...

Page 20: ...s but not included Minimum requirements of wall profile Base material 3 16 5mm Steel 1 4 6 mm Aluminum min 2 50 mm from the underside Reinforced concrete 2 50 mm Wood Expansion shell bolt min M6x85 UP...

Page 21: ...door header depending on type of doors The door is controlled with a push or pull arm system Note Consider all power wire entry locations and signaling wires before preparing back plate 10 1 PUSH arm...

Page 22: ...1020004 en US 2 0 Issue 2020 10 27 22 10 Mechanical installation...

Page 23: ...23 Issue 2020 10 27 1020004 en US 2 0 10 Mechanical installation...

Page 24: ...1020004 en US 2 0 Issue 2020 10 27 24 10 Mechanical installation...

Page 25: ...25 Issue 2020 10 27 1020004 en US 2 0 10 Mechanical installation...

Page 26: ...1020004 en US 2 0 Issue 2020 10 27 26 10 Mechanical installation...

Page 27: ...27 Issue 2020 10 27 1020004 en US 2 0 10 Mechanical installation...

Page 28: ...10 2 PULL arm system 1020004 en US 2 0 Issue 2020 10 27 28 10 Mechanical installation...

Page 29: ...29 Issue 2020 10 27 1020004 en US 2 0 10 Mechanical installation...

Page 30: ...1020004 en US 2 0 Issue 2020 10 27 30 10 Mechanical installation...

Page 31: ...31 Issue 2020 10 27 1020004 en US 2 0 10 Mechanical installation...

Page 32: ...1020004 en US 2 0 Issue 2020 10 27 32 10 Mechanical installation...

Page 33: ...33 Issue 2020 10 27 1020004 en US 2 0 10 Mechanical installation...

Page 34: ...1020004 en US 2 0 Issue 2020 10 27 34 10 Mechanical installation...

Page 35: ...tallation the wall socket shall be placed easily accessible from the operator If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in...

Page 36: ...nected the power wire 1 from the terminal 3 and protect the power with insulated tapes d Connect the adaptor wire 2 to the terminal 3 e Connect mains power to the adaptor Power wire 1 Adaptor wire 2 T...

Page 37: ...11 2 Control unit CU 37 Issue 2020 10 27 1020004 en US 2 0 11 Electrical connection...

Page 38: ...e spring according to the following information 12 2 App Connect mains power the operator will find its closed position and make sure the LED is on Before the learning procedure starts make sure that...

Page 39: ...12 2 2 Log in to the app with owner 39 Issue 2020 10 27 1020004 en US 2 0 12 Start up...

Page 40: ...a learn a new learn must be carried out Back check Latch check The back check will be automatically adjusted to 10 and 1 second before open position The latch check will be automatically adjusted to 1...

Page 41: ...12 2 4 Test 12 2 5 Settings 41 Issue 2020 10 27 1020004 en US 2 0 12 Start up...

Page 42: ...12 2 6 Add user 12 2 7 Remove user 1020004 en US 2 0 Issue 2020 10 27 42 12 Start up...

Page 43: ...12 2 8 Log in to the app with user 43 Issue 2020 10 27 1020004 en US 2 0 12 Start up...

Page 44: ...ng torque Not active Active Active Stop on stall 12V 24V 24V Select lock voltage Lock with power Lock without power Lock with power Select lock power Not active Active Not active Push and close 2s 25s...

Page 45: ...13 Cover Secure cover with screw Apply the ASSA ABLOY logotype to the cover see below 45 Issue 2020 10 27 1020004 en US 2 0 13 Cover...

Page 46: ...ons Door is in error LED light blinks Unlock the lock Mechanical lock is locked The motor starts but the door does not open Remove object Something jammed beneath the door Select lock release Electric...

Page 47: ...to know the importance of regulary scheduled maintenance to have a reliable and safe product Regular service and adjustments will ensure a safe and proper operation of an automatic door unit Thetable...

Page 48: ...The force required to prevent a stopped door from opening or closing shall not exceed 15 lbf 67 N measured 1 25 mm from the latch edge of the door at any point during opening or closing The kinetic en...

Page 49: ...of the sign The letters shall be 5 8 inch 16 mm high minimum Doors All doors shall be marked with signage visible from both sides of the door with the words AUTOMATIC CAUTION DOOR see illustration be...

Page 50: ...ions under the ASSA ABLOYbrand Ourproductsandservicesarededicatedtosatisfyingend user needs for safe secure convenient and sustainable operations ASSA ABLOY Entrance Systems is a division within ASSA...

Reviews: