45
ASSA ABLOY Hospitality
66 8003 015-3
9.3 Broadcasts
The
Broadcasted commands
dialog shows all commands that have been broadcasted
to the thermostats. The broadcast commands are listed in reverse chronological order.
Note:
The
Broadcasted commands
dialog is not automatically updated; press
F5
to
refresh it manually.
1. Go to
View/Broadcasts
.
Figure 35
2. To see details for a certain command, mark it in the list and click
Details
.
3. A
Broadcast Answers
dialog will be shown, with the concerned thermostats
or locks (depending on command) and their answer time.
Column
Description
Registration Number
Uniquely identifies the broadcasted command. The
registration number will be shown in the events the
command generates.
Command
# Answers
The number of locks that have answered the command
Last Transmission
Timestamp when the command was last broadcasted;
originally or due to a retry.
Succeeded
Yes if all locks answered
Cancelled
Yes if the command was cancelled by another broadcast;
e.g. a new
Set-Time command
cancels any previous
Set-Time command.
Buffered
Yes if the command has timed out. It has then been
buffered as a single-cast command for all locks that
have not answered.
Table 9