80-9357-0140-020 (09-10)
4
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2005, 2010, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
3000 Highway 74 East • Monroe, NC 28112
Tel: (877)-
• Fax: (800)-338-0965
www.nor tondoorcontrols.com
974-2255
ASSA ABLOY
Inverter Adjustments:
!
Based on function adjustment desired, use table above to
determine which POT is to be adjusted.
POT
FUNCTION
DESCRIPTION
OBSTR SENS
Obstruction Detection on Open
CW - Increase
CCW - Decrease
M/DLY
Motor Delay on Opening
CW - Increase
CCW - Decrease
P1
Motor Reversing Speed
CW - Increase
CCW - Decrease
H/O TM
Hold Open Time (5 - 30 Seconds)
CW - Increase
CCW - Decrease
P2
Push Recognition Sensitivity
CW - Increase
CCW - Decrease
H/O TQ
Motor Torque at Hold Open
Position
CW - Increase
CCW - Decrease
ON
1
2
WARNING
120 HIGH VOLT POTENTIAL PRESENT. MAKE
SURE POWER IS TURNED OFF DURING
INSTALLATION PROCEDURE.
Dip Switch Settings
1. Door Mounting -
2. Push Recognition -
ON - pull
OFF - push
ON - active
OFF - inactive
WARNING
Electric
Shock Risk
L2
115Y
L1
115/230VAC IN
MOTOR OUT
L2
230Y
U
V
W
STATUS LEDS
PUSH PULL
SW501
ON
H/O TQ
H/O TM
OBSTR
SENS
P1
M/DLY
P2
1
2
1
6
COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
(Adjustments made in the shaded
area should be performed by
Authorized Factory Personnel.)
Inverter Details
23. Turn circuit breaker to the “ON” position.
24. Rotate Open position magnet until door opens to desired position.