17.  Flip the dip switch on the inverter from the Pull to the Push 

position, see fig. 13.

13. Remove the four screws which secure the closer body to the 

backplate.

14. Slide the closer body away from the clutch assembly and chain.  

Make sure you do not remove pinion extension  when removing 
closer body from clutch mechanism.

15. Orient the closer body with “Latch” and “Sweep” valves toward 

conduit holes, and slide onto backplate so that closer pinion is 
inserted into pinion extension.  Some rotational adjustment of the 
pinion extension may be required to allow assembly of closer 
pinion and pinion extension.

16.  Replace and tighten closer body screws removed in step 12.  See 

fig. 12.

Fig.12

Sweep & Latch
Valves

Fig.13

Push/Pull Dip Switch

20. With door closed, slide Closed Position Magnet so it aligns with 

the Reed Switch.  See fig. 15.

21. Slide Open Position Magnet so it is 180° from the Reed Switch.  

See fig. 16.  Slide Open Position Magnet as needed to get proper 
door opening.

22. Continue to page 4.

Fig.15

Closed Position

Magnet

Reed Switch

Fig.16

Open Position

Magnet

Reed Switch

Pinion

Extension

Cam

Driver

18.  Verify switch is in the “ON” position for the circuit breaker and 

activate unit.

19.  Immediately after activating the unit, watch the Cam Driver, fig. 

14, as it rotates around.  As soon as the Cam Driver contacts the 
Pinion Extension, flip the circuit breaker switch to the “RESET” 
position.