3
80-9357-0140-020 (09-10)
17. Flip the dip switch on the inverter from the Pull to the Push
position, see fig. 13.
13. Remove the four screws which secure the closer body to the
backplate.
14. Slide the closer body away from the clutch assembly and chain.
Make sure you do not remove pinion extension when removing
closer body from clutch mechanism.
15. Orient the closer body with “Latch” and “Sweep” valves toward
conduit holes, and slide onto backplate so that closer pinion is
inserted into pinion extension. Some rotational adjustment of the
pinion extension may be required to allow assembly of closer
pinion and pinion extension.
16. Replace and tighten closer body screws removed in step 12. See
fig. 12.
Fig.12
Sweep & Latch
Valves
Fig.13
Push/Pull Dip Switch
20. With door closed, slide Closed Position Magnet so it aligns with
the Reed Switch. See fig. 15.
21. Slide Open Position Magnet so it is 180° from the Reed Switch.
See fig. 16. Slide Open Position Magnet as needed to get proper
door opening.
22. Continue to page 4.
Fig.15
Closed Position
Magnet
Reed Switch
Fig.16
Open Position
Magnet
Reed Switch
Pinion
Extension
Cam
Driver
18. Verify switch is in the “ON” position for the circuit breaker and
activate unit.
19. Immediately after activating the unit, watch the Cam Driver, fig.
14, as it rotates around. As soon as the Cam Driver contacts the
Pinion Extension, flip the circuit breaker switch to the “RESET”
position.
Fig.14
Instructions continued on page 4.