80-9360-1043-020 Rev 1 05/21
Copyright © 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
4
6000 Series
Programming Instructions
1. With building power feed turned off, route
120VAC wiring through conduit holes in back
plate for concealed wiring or through the Union
Assembly knock-out for surface wiring and
connect conduit to Conduit Assembly.
2. Connect 120VAC power to terminal strip on top
of Conduit Assembly: HOT to “+”, NEUTRAL to
“-”, and GROUND to green ground screw.
(Figure 1)
NOTE: Union Assembly may need to be
removed for ease of access. Remove
AND SAVE
(4) 8-32 x 5/16" Philips pan head screws.
3. Wire in any devices needing outputs, such as
electric strikes, mag locks, exit devices, door
open position output, etc to green terminals on
top of control board. (Figure 2)
4. Reinstall Union Assembly using (4) 8-32x5/16"
screws previously removed.
5. Turn on building power to unit.
6.
Confirm ON/OFF/HO switch is in ON position
before proceeding to Setup. (Figure 3)
NOTE: On control board there should be one
solid red LED for POWER and one white LED
that flashes every 1.5 - 2 seconds for STATUS.
CLOSE button of Setup Buttons should be
flashing orange continuously.
NOTE: If red LED is flashing, refer to
Troubleshooting section of this manual or
contact Technical Product Support.
Initial Wiring
Conduit Hole
Terminal Strip
Figure 1
Figure 2
Figure 3
Shown in
ON Position
Door Setup
REQUIRED
GO
Status LED
Input Terminals
WARNING: Door may begin to move immediately
when selector mode switch is changed. An open
union assembly door has potential to pinch fingers
if hand is not withdrawn quickly when adjusting
selector mode switch. There is also potential of
damaging or breaking door if door is open during
closing cycle of a pull side assembly.