6000 Series
Wiring Diagrams
24VDC Fail Safe Electric Strike or Electromagnetic Lock
(change factory pre-wiring to illustration below - move NO to NC on controller)
• Door is normally closed and latched.
• Activating switch will unlock electric strike or mag lock and door will
automatically open. Door will close after hold open time delay has expired.
• Door will remain unlocked during power failure.
• Activation can be wall switch, card reader, key switch, etc (Normally open
momentary dry contacts).
• Current draw at Power Outputs not to exceed 1.3A.
• To turn on relay (Relay 2), Latch Retraction (Output
Connections, page 14) and/or Open Delay (Set options,
page 8) features must be turned on using adjustment
procedures on pages indicated.