55
Problem, cause, solution
EN
No reaction to control signal
Problem
Possible cause
Solution
The lock is not unlocked, even
though the
unlocking
control
input is activated.
The lock is simultane-
ously connected via
Hi-O Technology™ bus
.
During operation via
Hi-O Technology™ bus
with
the IO module, detach the lock’s grey connec-
tion cable on the functionless
unlocking
control
input (follow separate instructions on the
lock).
The voltage has just
been switched on on
the lock.
Wait until the lock is ready for operation after a
restart (follow separate instructions on the
lock).
The lock was discon-
nected from the
Hi-O Technology™ bus
with
Plug & Play
mode
activated..
Deactivate Plug & Play via DIP switch 3
(“DIP switch”, page 42).