Functions and operation
EN
Settings on the rotary switch
The rotary switch (Fig. 3 Pos. 1) can be used to adjust the
following settings:
· the unlocking duration and
· the meaning of the status signals through the two out-
puts (Fig. 6):
· Output 4 reacts to the bolt position and
· Output 5 reacts to the door position.
With the use of the adapter board, the non-isolated
outputs are switched to potential-free outputs. The
terminal assignment for output 4 / 5 without adapter plate
is shown in Tab. 1. The conversion to potential-free
outputs is described in the chapter “Connection assign-
ment of the adapter board”, page 34 .
Output 4 is set to low in idle mode.
Output 5 is set to high in idle mode, so that an alarm or
tampering signal can be issued during a power failure, if
the corresponding rotary switch position was set.
Switch
position
Unlocking
duration
Output 4
(Status signal 4)
Output 5
(Status signal 5)
0 (default) 0.5 s
Locked
low
Unlocked
high
Door closed
low
Door open
high
1
2.0 s
2
4.0 s
3
0.5 s
Locked and
door
closed
low
Locked and
door
open high
Unlocked and door
closed high
Unlocked and door
open
high
No signal
high
Alarm or tampering
low
4
2.0 s
5
4.0 s
6
0.5 s
No signal
high
Unlocking via cylinder
low
7
2.0 s
8
0.5 s
No signal
high
Alarm, tampering or
unlocking via cylinder
low
9
2.0 s
A
not defined
B
not defined
C
not defined
D
not defined
E
0.5 s
Locked and
door
closed
low
Locked and
door
open high
Unlocked and door
closed high
Unlocked and door
open
high
Only with OEM version U4:
No signal
high
Alarm or tampering
low
F
–
May not be adjusted
1
Fig. 3 :
Rotary switch
4
5
3
2
1
Tab. 1 :
Meaning of rotary switch
positions