7
80-9360-6004-152 04/18
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
DC6200 & DC6400 Series Closers
Installation Instructions
A10 Heavy Duty Non-Hold Open Arm
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
3
Adjustments
Adjust Spring Power According to Chart
DC6200 Size 1-6 Adjustment (Figure 10)
DC6400 Half Size Adjustment as desired
• All DC6200 closers are factory set at an
approximate Size 3.
Full Cover (Standard)
Slim Cover (Option M76)
Figure 10
Figure 11
Size of Door
No. of Full (360°)
Turns Clockwise of
Power Adjuster
Equivalent Closer
Size (Approx.)
Interior
Exterior
In-Swinging
2' 4"
(712)
2' 6"
(764)
4
2
2' 6"
(764)
3' 0"
(915)
8
3
3' 0"
(915)
3' 6"
(1067)
12
4
3' 6"
(1067)
4' 0"
(1219)
16
5
Figure 12
4
Cover Installation
Full Cover (Standard)
Slim Cover (Option M76)
Install Cover (Figure 11)
Slip cover over closer. Hold tightly against
closer mounting surface. Secure on each
side with 6-32 x 1/4 PBHMS screws.
Slim Cover Option M76 only (Figure 12)
Position spindle cap over unused spindle
and secure with truss head screw.
• Adjust closer as necessary for door size
using this chart.
• Readjustment may be required to suit
prevailing conditions.