5
80-9360-6004-152 04/18
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
DC6200 & DC6400 Series Closers
Installation Instructions
A10 Heavy Duty Non-Hold Open Arm
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
2
Installation
MAIN ARM
Pin Hole
End
Countersunk
Holes
NOTE ARMS WILL
FORM A “V” POSITION
Rotate
approximately
5°
1/4-20 x 1/2 OHMS (2)
Pins
(2)
4. Position Arm on Closer. (Figure 5)
Main arm projects straight out at 90° angle to
door.
5. Preload and Fasten Arm to Frame.
(Figure 6)
Close door, swing arms to align holes in arm
bracket with pre-drilled holes on frame and
install attaching screw.
NOTE: Arms will form a “V” position.
Extended Maintenance
Lubricate Arm periodically at shaded points
with a drop or two of appropriate lubricant.
Figure 5
Figure 6
MAIN ARM
Pin Hole
End
Countersunk
Holes
NOTE ARMS WILL
FORM A “V” POSITION
Rotate
approximately
5°
1/4-20 x 1/2 OHMS (2)
Pins
(2)
1/4-14 x 1-1/2
OH Self-Drilling
(2)