ML20700 PWI/PIP Series Mortise Lock
22
Copyright © 2015 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Hinge Installation
Order of installation may vary. Refer to appropriate sections for instructions.
Hinge-side harness connectors:
• 4-pin male Molex connector
• 6-pin male Molex connector with ground wire
Lock-side harness connectors:
• Ring terminal
• (2) 4-pin connectors:
• 4-pin Molex connector
• 4-pin connector
Notes:
• Connectors go on only one way. They cannot be plugged to incorrect position.
• Do not force and do not offset connectors.
• Be sure they are completely seated (flush).
C
Door Harness Installation
Order of installation may vary. Refer to appropriate sections for in-
structions.
1. Prop door open.
2. Tape the two lock-side 4-pin connectors to the ring terminal.
3. Using the ring terminal, carefully route the assembly through the
door channel to the lock.
4. Remove tape from ring terminal and door harness connectors.
Hinge-side harness connectors:
• 4-pin male Molex connector
• 6-pin male Molex connector with ground wire
Lock-side harness connectors:
• Ring terminal
• (2) 4-pin connectors:
• 4-pin Molex connector
• 4-pin connector
Notes:
• Connectors go on only one way. They cannot be plugged to
incorrect position.
• Do not force and do not offset connectors.
• Be sure they are completely seated (flush).
D
6-pin F
6-pin F
6-pin M
Cable
: CAT 5e,
26 AWG stranded,
shielded, 100ohm
4-pin M
4-pin F
4-pin F
Drain Wire
PoE Hinge (Patent Pending)
Ring Terminal Secured
to Lock Mounting Plate
Ground
6) PIP (PoE) Installation Wiring (Continued)
RJ45-M
Summary of Contents for Corbin Russwin Access 700 ML20700 PIP Series