8
of 8
Printed in the U.S.A.
Patent pending and/or patent www.assaabloydss.com/patents
Copyright © 2022, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Hanchett Entry Systems, Inc. is prohibited. 80-0180-497_1
adamsrite.com |
800 626 7590
[email protected]
10027 S. 51st Street, Ste. 102 Phoenix, AZ 85044 USA
WARNING
FCC Statement
This equipment has been tested and found to
comply with the limits for a class B digital device,
pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio
frequency energy and if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between
the equipment and receiver.
3. Connect the equipment into an outlet
on a circuit different from that to
which the receiver is connected.
4. Consult the dealer or an experienced
radio/TV technician for help.
Operation with non-approved equipment is likely to
result in interference to radio and TV reception. The
user is cautioned that changes and modifications
made to the equipment without the approval of
manufacturer could void the user’s authority to
operate this equipment. To comply with FCC and
Industry Canada RF radiation exposure limits for
general population, the module must be installed to
provide a separation distance of at least 20cm from
all persons and must not be colocated or operating in
conjunction with any other antenna or transmitter.
This module is labeled with its own FCC ID and
IC Certification Number. If the FCC ID and IC
Certification Number are not visible when the module
is installed inside another device, then the outside
of the device into which the module is installed
must also display a label referring to the enclosed
module. In that case, the final end product must
be labeled in a visible area with the following:
Contains FCC ID: VC3-R100V3
Contains IC: 7160A-R100V3
IC Statement
This device complies with Industry Canada
license-exempt RSS standards(s). Operation
is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including
interference that may cause undesired operation.
Conformité aux normes IC
Cet appareil est confrome avec Industrie Canada
exempt de license RSS standard(s). Son fonctionnement
est souimes aux deux conditions suivantes:
(1) cet appareil ne peut causer d’interférences, et
(2) cet appareil doit accepter toute interference, y
compris des interférences qui peuvent provoquer
un fonctionnement indésirable du périphérique.
CE Declaration of Conformity
content.assaabloyusa.com/doc/AADSS1179512&.pdf
Product Specifications
Approvals
CE, FCC, IC
Wireless Frequency
2.4GHz, IEEE 802.15.4, using AES 128-bit encryption
AA Lithium
Energizer L91 Rated 1.5 VDC, 3 Ah
NOTE: Replace Battery With Energizer L91
batteries only. Use of another battery may
present a risk of fire or explosion.
CAUTION: Risk of fire and burns. Do not recharge,
disassemble, heat above operating temperature
or incinerate. Keep battery out of reach of
children and in original package until ready
to use. Dispose of used batteries promptly.
Battery Life
2+ years (45,0000 cycles)*
*All battery life claims are approximate and based
on a set configuration profile. Battery performance
is based on pre-defined system settings such
as battery chemistry and battery model used,
credential presentation settings (LED/buzzer),
UHF polling period, UHF status intervals, and
operations per day. Actual battery performance
will vary and depends on the factors above.
HID® multiCLASS SE® Technology
Credentials Supported
• High Frequency (13.56 MHz)
• HID iCLASS®
• HID iCLASS SE® (SIO-enabled)
• HID iCLASS® Seos™
• HID MIFARE® SE
• HID DESfire® EV1 SE
• MIFARE CLASSIC
• DESfire® EV1
•
Low Frequency (125 kHz)
• HID Prox®, AWID, EM4102, ioProx
NFC/BLE*
Mobile – enabled credentials
Reader is compatible with HID Mobile
Access version 3.76 and later using mobile
devices with BLE version 4.2 and later
Environmental
Operating Temperature
(both products)
• 14° to 140° F [-10° to 60° C]
Operating Humidity
(both products)
• 0 to 93% relative humidity non-condensing
Certifications
• UL 294 Listed – Indoor Rated
• UL 294 Salt Spray Test Compliant
• Tested to IP65 (Reader Only)
• FCC Part 15 & Industry Canada Compliant
• CE RED – Radio Equipment Directive – 2014/53/EU
UL294 Performance Levels
• Destructive
Attack:
Level I (No Attack Test)
• Line Security:
Level I (No Line Security)
• Endurance:
Level IV (100,000 Cycles)
• Standby Power:
Level I (No Secondary Power)
Safety and Emissions
• FCC 47CFR Part 15, subpart C
• IC RSS-102
• RSS-210
• RSS-247
• RE Directive 2014/53/EU, EN 301 489-1, EN 301 489-3,
EN 300 440, EN 300 330, EN 300 328, EN 62368-1, EN 62479