Aperio Hub Specifications
Approvals
CE, ETL, FCC, IC, C-Tick
Safety & Emissions
FCC 47CFR Part 15 subpart B and subpart C;
IC RSS-210 EN ETSI 301 489-17 v2.1.1; ENETSI
300 328 v1.7.1; EN 60950-1 ed.2 2007
Dimensions
3-1/8" x 3-1/8" x 1-3/16" [82mm x 82mm x 37mm]
Power Supply
8–24 VDC
Current
250 mA minimum
Internal Antenna
2 cross polarized dipoles
External Antenna
(Part No. EXT-10-ANT) One reverse polarity SMA
external antenna connector. Optional antenna
type dipole with max antenna gain of 3.9dBi
Radio Standard
IEEE 802.15.4(2.4GHz) – 15 channels (11-25)
Encryption (RadioCommunications)
AES 128 bits
Wireless Operating Range
Up to 50 ft
Receiver Sensitivity
-100dBm 20% PER
Wireless Transmit Power
10 d Bm/MHz
Class of Protection
IP 20
Operating temperature
41°F to 95°F [5°C to 35°C]
Humidity
< 95% non-condensing
Status
LED (red/green/yellow)
LED Codes
APERIO LED LOCK CODES
(1) ONE Yellow Flash
Card read
(1) ONE Green Flash
Access Granted
(5) FIVE Yellow (1) ONE Red
Force Closed
(in open mode)
Continuous Yellow Flashes
(.25 sec every second)
Comhub busy
(1) ONE Red Flash
Access Denied
(AC Online)
(3) THREE Red Flash
Access Denied
(AC Offline)
Continuous Red Flashes
(.125 sec every second)
Lock is Blocked
(when closing)
(10) TEN Red Flashes
Error in Lock
Continuous Yellow Flashes
(.25 sec every 5 seconds)
Low Battery
Continuous Red Flashes
(.25 sec every 5 seconds)
Dead Battery
APERIO LED HUB CODES
Steady Green
Online
Steady Green
+ (1) ONE Red Flash
Lock Offline
Steady Green
+ (2) TWO Red Flashes
Access Control Offline
Steady Green
+ (3) Three Red Flashes
Access Control &
Lock Offline
Flashing Yellow
UHF Communication
For placement of hub, see AH20/AH30
Installation Instructions
Connecting the Hub
The following applies only to Aperio factory paired kits with AH20 Hubs.
Connect the Wiegand D1, D0, red, and green LED signals.
Note: The Green LED input is used to grant access to the cabinet lock.
If the Green LED signal is not available to indicate approved access,
the approval input can be activated by a relay with “NO” attached
to Green LED and “C” to GND. The Red LED input is used to indicate
access denied. If the RED LED signal is not connected, the lock
will flash RED three times when a non-approved card is presented
indicating loss of connection to the hub rather than access denied.
Any other codes may be reference on the LED reference card.
For questions regarding installation of the hub such as hub
placement, coverage area, or materials that may interfere or
reduce range, please review the hub installation instructions:
content.assaabloyusa.com/doc/AADSS1177359
NOTE:
This hub has not been evaluated by UL.
7