How does the proactive display work?
This proactive display of the events in the display only takes place during the operating mode
display. The event and error display is not active during sensor display or in the menu display.
If several events are active at the same time, they are displayed one after the other for 2 seconds
each.
The displayed messages refer to the section "Parameter reference or error numbers" (section:
6.6) of this document.
Examples of proactive display
►
The "250 ProgramInit" message is displayed immediately after the control unit is switched
on, in order to communicate the correct start of the control.
►
When the control unit is switched off, the message "224 FU Span.Fhl" is briefly displayed
when the voltage supply is broken before the display goes out.
►
If both limit switches (OPEN and CLOSE) are activated (not to +24 volts), the display shows
"215 End positions undefined" to signal the faulty function or the wrong connection. This
important error message is not removed until the control unit is rebooted, or until a
functioning motor run has been started.
►
If some special inputs are activated for an extended period of time (than usual), the
reference is also displayed:
For example, if the stop button is active for more than 2 seconds, "161 Instant Stop" is
displayed. The safety contact edges or the light barrier are also displayed after a longer
activation period.
5.3 Information on menu display
The menu selection can be found by means of the rotary and selection switch. This offers the
following options:
1. Identification
Master version
Installed program versions
Gate Type
Control variant
Serialnumber
Individual serial number of the control system and PAN
Motor Controller
Program version of the motor controllers
Peri.Controller
Program version of the periphery controller
Parameter Set
Version of the installed table of parameters
Bootloader Motor Version of the boot loader program from the motor controller
Bootloader Peri.
Version of the boot loader program from the periphery controller
2. Service Menu
Password Input
Access (password) for service technicians and activation of other
or additional performance characteristics
Language
Selection of a different national language in the LC display
Mot.RotationDir.
Change of the motor direction of rotation left/right
Motor Speed
Selection of the maximum motor speed in automatic mode
PWM Boost
Increase of motor output voltage at low no. of revolutions
Par. Restore
Resetting the adjustable parameters to their factory settings
3. Diagnosis
Gate State
State of control system/gate, inputs and outputs as well as of
maintenance
information
Sensor State
Setting and state of connectable sensors
System Logbook
Table of the most recent events and faults
Event Logbook
Table of the events (and faults) which have occurred since the last
restart of
the control system