background image

R·I·T 

Title: ASML Stepper              

Semiconductor & Microsystems                           
Fabrication Laboratory 

RevisionB                            Rev Date: 12/21/2010

 

 

RIT SMFL 

 

Page 2 of 11 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 Reticle Pre-Alignment Marks 

 
 
 
 
 

 

 

 

 

 

 

 

 

 Reticle Barcode 

 
 
 

 

 

 

 

 

 

 

 

 Reticle Alignment Marks 

 
 
 

 

 

 

 

 

 

 

 

 

 
 
 
   

 

 

 

 

 

 
 

4.2

 

Reticle  Bar  Code  –  The  reticle  barcode  is  read  as  the  reticle  is  removed  from  the  reticle 
carrier.  Reticle bar code information is specified in the stepper job. 

 

4.3

 

Reticle Pre-Alignment Marks – Two Pre-alignment Marks are located 135.5mm apart near 
the corners of the reticle.  They are used to pre-align the reticle to the reticle table. 

 

4.4

 

Reticle Alignment Marks - Two Reticle Alignment Marks, M1 and M2, are located 139mm 
apart near the left and right edges of the reticle.  After the reticle is pre-aligned on the reticle 
table, the Reticle Alignment Marks are aligned to the permanent fiducial marks F1 and F2, 
located on the fiducial plate on the wafer table. 

 
4.5

 

Wafer  Zero  Level  –  The  ASML  Stepper  utilizes  zero  level  marks  that  are  patterned  and 
etched  into  the  wafer  before  any other steps.  An etch depth of 1200A  +/-  10% allows the 
stepper to recognize the marks.  It is possible to pattern the zero level at the same time as the 
first level, but overlay accuracy will be reduced since the first level is not aligned to the zero 
level.  This is because the zero level is defined by a separate reticle. 

 
4.6 

Wafer  Global  Alignment  -  The  wafer  alignment  marks  W1,  W2,  etc,  are  exposed  on  the 
zero layer and etched into the wafer.  Two of these marks are sufficient but up to 25 may be 
used  on  a  single  wafer.    If  more  than  two  marks  are  used,  the  stepper  will  find  a  best 
alignment  and  expose  all  die  using  the  same  settings.    The  stepper  uses  through  the  lens 
alignment of the wafer and the reticle. 

 

||||

||||

||||

|||

 

R

IT

 

R

IT

 

Summary of Contents for PAS 5500

Page 1: ...ment may result in loss of privileges 2 REFERENCE DOCUMENTS Batch Control PAS 5500 Training Module Reticle Design Manual PAS 5500 User Guide PAS 5500 Job Definition PAS Global Alignment Strategies PAS 5500 Steppers up to and including 300 Stepper Introduction 3 DEFINITIONS n a 4 TOOLS AND MATERIALS 4 1 General Description The ASML PAS 5500 200 is a 5x reduction i line stepper set up for exposure o...

Page 2: ...nment Marks are aligned to the permanent fiducial marks F1 and F2 located on the fiducial plate on the wafer table 4 5 Wafer Zero Level The ASML Stepper utilizes zero level marks that are patterned and etched into the wafer before any other steps An etch depth of 1200A 10 allows the stepper to recognize the marks It is possible to pattern the zero level at the same time as the first level but over...

Page 3: ... 5 1 1 The ASML uses ultraviolet light as well as lasers and should only be operated with all of the covers closed Safety glasses should be worn at all times 5 1 2 The ASML stepper had mechanical hazards Do not operate with open covers and do not open any covers during operation 5 2 Hazards to the Tool 5 2 1 Never open or service the wafer stage since serious damage to the tool can occur 5 2 2 Nev...

Page 4: ...te 12 21 2010 RIT SMFL Page 4 of 11 6 INSTRUCTIONS 6 1 Starting the System 6 1 1 Swipe the tool in on the Card Swipe System 6 1 2 Verify that the computer is on 6 1 3 Make sure that the computer is on the Main Menu if not select 0 Exit Do not exit from the Main Menu Unload Load Reticle Changer ...

Page 5: ... a 45 degree angle Always support the reticle box on the bottom to prevent reticles from falling out 6 2 3 Carefully open the reticle box The clear top is released from the base by sliding the 4 clamps underneath the base Load the reticles chrome side down with the pre alignment stars facing out Never touch the surface of a reticle Close the reticle box and make sure it is secured before lifting D...

Page 6: ...rol and 1 Define Batch 6 4 2 The Batch ID is the name that you use to identify your wafers 6 4 3 The Job Name is the name of the stepper job that you want to use Click the Select button scroll down select the job and Accept at the top of the screen Writing a stepper job is detailed in a separate document 6 4 4 Click on the line to the right of Layer ID Select the Layer Number that you want to expo...

Page 7: ...is not fully raised 6 5 2 Place the empty cassette back on the tool All 4 stations should have a cassette 6 6 Unloading Reticles 6 6 1 To remove the reticle box from the machine under Main Menu select Mat Hdl from the top of the screen and then 3 Exchange Reticle Box Click the Unlock button in the middle of the screen to unlock the reticle box 6 6 2 Remove the box by lifting straight up 2 cm tilti...

Page 8: ...Process Data in your stepper job to enter a layer shift in microns See Section 6 8 of the ASML PASS 5500 Job Creation Manual 7 APPROPRIATE USES OF THE TOOL 7 1 No backside coated wafers only wafers with clean backs may be processed in this tool 7 2 No polyimide or SU8 may be processed in this tool 8 ATTACHMENTS 8 1 Dose to Clear Test Exposure Matrix 8 1 1 This test is done with or without a mask a...

Page 9: ...he screen used to define a batch 8 2 FEM Focus Exposure Matrix 8 2 1 From the Main Menu select 6 Test Manage 8 2 2 Select 1 Run Test 8 2 3 Move to the top of the directory by clicking Up 8 2 4 Select Projection Systems 8 2 5 Select FEM Developer Customer 8 2 6 Select Accept at the top of the screen 8 2 7 Input desired values for matrix size energy increment focus and the number of die to be expose...

Page 10: ...est Que 8 3 10 Select Select 8 3 11 Scroll down until you see daily RIT Characters are case sensitive 8 3 12 Select Accept at the top of the screen 8 3 13 Select Accept again and the test will run 8 3 14 Select Exit twice to return to the Main Menu 8 4 Procedure for Creating a Zero Level 8 4 1 Load the Combi Reticle 8 4 2 Select your stepper job 8 4 3 Select Layer ID 8 4 4 Select Zero Layer to exp...

Page 11: ...rosystems Fabrication Laboratory Revision B Rev Date 12 21 2010 RIT SMFL Page 11 of 11 REVISION RECORD Summary of Changes Originator Rev Date Original Issue Sean O Brien A 07 20 2010 Clarified some of the instructions Sean O Brien B 12 21 2010 ...