3.1.2.2 From Marshalling Box to SMC02 Console
The ASL SMCLEAD is built according to the requirements below, and can be ordered
separately from Application Solutions Limited in two variants:
•
SMCLEAD-5M:
Five metre long lead with marshalling box connections terminated in ferrules ready for
connection.
SMC02 end terminated with ITT TNM 6S16-00191SL fitted with T2P24FC1LT contacts and
TNA16CCSE00L end bell.
•
SMCLEAD-20M:
Twenty metre long lead with marshalling box end clean cut, for termination to the correct
length during installation.
SMC02 end terminated with ITT TNM 6S16-00191SL fitted with T2P24FC1LT contacts and
TNA16CCSE00L end bell.
The following requirement should be observed when assembling the cable for connection of the SMC02
console to the marshalling box.
Signals
Cable Description
Suggested Type
Microphone Audio
1 twisted pair
Listen-In Audio
1 twisted pair
Microphone Data
1 twisted pair
Other Signals
7 cores using any available pairs
LSF sheath. Multi-pair cable with overall foil screen.
Overall diameter compatible with ITT TNM 6S16-00191SL.
Connector to SMC02:
ITT TNM 6S16-00191SL fitted with T2P24FC1LT contacts and TNA16CCSE00L end bell
3.1.2.3 Cabling to an Intellevac ACU
Please refer to the Intellevac ACU Installation Guide [
Table 5-9
].
3.1.2.4 Cabling to an VAR8-ACU
Please refer to the VAR8-ACU Installation Guide [
Table 5-6
].