Asko WM25 Service Manual Download Page 11

Service manual WM25

11

Components and measurement values

Item number

Component

Measurement value

Comments

80 655 63

Motor 50 Hz

Resistances:
Pin 2-3 stator 1.41 Ω
Pin 1-3 stator 0.57 Ω
Pin 4-5 rotor 1.54 Ω 
(measured diagonally 
across the collector)
Pin 6-7 tacho 135 Ω

All resistance values have tolerances of 
±8 %.

80 637 33

Motor 60 Hz

Resistances:
Pin 2-3 stator 1.05 Ω
Pin 1-3 stator 0.58 Ω
Pin 4-5 rotor 1.75 Ω 
(measured diagonally 
across the collector)
Pin 6-7 tacho 135 Ω

All resistance values have tolerances of 
±8 %.

80 617 06

Heating Element 
2000 W

28.4 Ω

80 761 02

Thermistor

6.1-3.8 k
Ω (at room temperature 
20 – 30°C)

The thermistor for temperature reading 
is located between the motor cradle and 
the container. The thermistor measures 
and controls the water temperature that 
can vary from 0 to 90°C. The element is 
disconnected if the thermistor is short-
circuited or disconnected from the 
programme control card.

88 012 63.

Drain pump 50 Hz

144 Ω.

The drain pump is combined with an 
integrated fine filter trap, which can be 
cleaned by the user. If the drain pump 
has run for 180 seconds during drain-
ing, the programme stops, resets and a 
trouble code is indicated in the display 
(on machines without a display, the LEDs 
flash).

88 012 64.

Drain pump 60 Hz

76 Ω

See above.

80 782 21

Level Switch

Electro mechanical level switch with 
two levels, see wiring diagram. Indicates 
levels for door opening, heat and overfil-
ling.   

80 616 64

Pressure sensor

0.5 V out from the 
sensor (at 0 bar pressure 
and 230 V mains vol-
tage, measurement car-
ried out with the drain 
pump running to ensure 
0 level is reached)

ASKO level sensor type 1166. Controls 
intake and level

80 762 02

EMC filter with inductor 
50/60 Hz

The filter eliminates interference to and 
from the machine.

80 762 01

Inlet valve

3,7 kΩ ± 0.5 kΩ

3 way inlet valve 10 litres / minute

80 616 79

Door lock

122 Ω

The door lock is electro mechanical and 
equipped with a magnet.

80 771 27

Control Unit WM25.1

80 771 28

Control Unit WM25.2

80 771 29

Control Unit WM25.3

Summary of Contents for WM25

Page 1: ...ce 6 Options and settings 6 Variant settings 7 Test programme 8 Fault indications 10 Components and measurement values 11 Technical data 12 Wiring diagram 13 Appendix Timer diagram WM25 This service m...

Page 2: ...Service manual WM25 2...

Page 3: ...from market to market The type designation is the most important factor for identifying the machine type The type designation can be found on the machine plate which is located inside the machine s d...

Page 4: ...ions for use Settings 2 designations di er depending on the market see directions for use h min Power Super rinse W 6 2 3 2 Q U A T T R O 1 3 0 0 R P M Cold 30 800 800 1300 1300 40 50 60 95 White Colo...

Page 5: ...consump tion approx litres Energy Pro gramme time approx min Programme 1 Yes Long 95 Long 1400 1 1 2 5 72 2 2 175 Programme 2 No Long 60 Long 1400 1 1 2 5 69 1 14 140 Programme 3 No Short 60 Long 140...

Page 6: ...ng Settings 400 400 800 800 1000 1000 1400 1400 It is possible to select spin speed between 400 and 1400 rpm No spin and No draining option depending on machine type Spin at 400 800 rpm means a short...

Page 7: ...L3 and L4 light when automatic door open ing is selected 3 Con rm your selection by pressing the start stop button S1 Super rinse or Delayed Start 1 Hold S5 or S6 pressed in when you switch on the mai...

Page 8: ...osed 6 Press the start stop button S1 The entire display goes out except L6 by the start stop button which starts to ash and continues to do so for the remainder of the test programme Valve 1 opens fo...

Page 9: ...ns Indication of faults Fault indication symp tom Cause LED L1 and L2 ash Warming up fault The temperature rises to 20 C within one minute LED L2 ashes Warming up fault The temperature has not increas...

Page 10: ...e or press the Key button door open to empty the machine Service action 1 If the pump only runs for a short while ap proximately 20 seconds this indicates a fault in the level system Check the level s...

Page 11: ...control card 88 012 63 Drain pump 50 Hz 144 The drain pump is combined with an integrated ne lter trap which can be cleaned by the user If the drain pump has run for 180 seconds during drain ing the...

Page 12: ...1 phase 10 A Element power See type plate Water pressure 0 1 1 MPa 1 10 kp cm 10 100 N cm Wash drum and liquid compartment material Stainless steel Outer casing material Powder coated and hot galvaniz...

Page 13: ...ontents thereof must not be imparted to a third party nor be used for any unauthorized purpose Contravention will be prosecuted Asko Cylinda AB Dimensions Type etc Pos Material Name of item Qty Dens K...

Page 14: ...6 Program 7 Program 8 Program 9 Program 2 Program 3 Program 4 Program 5 P5 TO5 12 P5 P9 4 5 Program 1 P3 30 TO2 P3 30 P3 12 400 rpm P3 30 P3 30 TO2 P5 TO5 12 P5 P9 4 5 P3 30 TO2 P5 TO5 12 P5 P9 4 5 P3...

Page 15: ...el Program 6 Program 7 Program 8 Program 9 Program 2 Program 3 Program 4 Program 5 P3 ca 2 800rpm P3 ca 8 800rpm 30 Program 1 P3 30 TO2 P3 30 P3 12 400 rpm P3 30 P5 P9 4 5 P3 30 TO2 P6 TO5 P6 P4 4 5 P...

Page 16: ...Clockwise 9 seconds on 6 seconds off counterclockwise 9 seconds on 6 seconds off 40rpm Normal action Clockwise 12 seconds on 3 seconds off counterclockwise 12 seconds on 3 seconds off 49rpm Gentle act...

Reviews: