44
Dryer motor
1. Function
• The motor rotates the drum using the belt as well as the fan to ex
hause humid
air.
• This is a shunt AC motor. When the motor begins to run, a centrifugal switch shorts out the operation
coil.
• The centrifugal switch also supplies power to the heater. Thus, if the motor stops, the heater goes off
also.
2. Specification
• Shunt type 1/3 HP AC motor with centrifugal switch
• Rotational speed : more than 1600 rpm with load
• No load : 190W, 4.9A at 120V• Type name : 60T
• Full load : 555W, 6.1A at 120V
• Type name : S58NXSDD-6989
3. Checking method of malfunction
• If the drum rotates and exhaust air is expelled as soon as you start the unit, the motor is in normal
operation.
• If the drum fails to rotate;
1
Remove
the top plate
and check if the belt is damaged.
2
Check if the door switch is in normal operation.
3
Remove the drum and check the thermostat fan.
4
Check the belt switch.
5
Run the unit while you press the lid of the belt switch and see if the motor starts operating.
• If a fault is found in any part mentioned above, replace it and check the operation of the motor (5).
• If no fault is found but the motor still fails to operate
5
, replace the motor.
Fan connection axis
Belt operation axis
Fan connection
Belt assembly
Part Code : 36189L5D00
Summary of Contents for TL751 XXLT
Page 1: ...Service Guide Tumble dryer Version1 2008 02 13 Asko TL751 XXLW TL751 XXLT...
Page 29: ...28 ELECTRIC DRYER TL751 WIRING DIAGRAMS...
Page 53: ...52 TERMINAL BLOCK 1 Remove terminal block cover 2 Remove 3 screws...
Page 57: ...56 LAMP ASSEMBLY 1 Remove 1 screw...
Page 60: ...59 4 Door Switch...