Model D1976
(DW 955)
Page
Date
2000-06
5
FAULT CODES
Blinking lights and an F-code in the LED window indicate a machine fault.
Code
Blinking Lights
Problem
F1
L3 and L7
Heating element
F2
L1–L8
Overfill
F3
L4 and L5
Thermistor fault (heater control)
F4
L1–L4
Water inlet
FAULT-TRACING PROGRAM
The functions of the electrical components can be tested by
pressing S6 five times then pressing
one
of the following:
Press
to test
S2
inlet valve 2
S3
inlet valve 1
S4
combi-dispenser
S5
heating element
S6
circulation pump
S7
outlet pump
S8
fan motor and wax motor
Stop the fault-tracing program by pressing S13.
LINKS ON THE PROCESSOR BOARD
(for program variations)
These diodes should be cut for proper U.S.iInstallation:
Link 955:
DW955, processor board layout
Link USA:
USA processor board layout
S = Pushbutton switch L = Indicator light
PROGRAMS
Summary of Contents for D1976
Page 9: ...Model D1976 DW 955 Page Date 2000 06 9 This page intentionally blank ...
Page 10: ...Model D1976 DW 955 Date 2000 06 Page 10 CASING AND RELATED PARTS 9 11 1 2 3 4 5 6 7 8 10 ...
Page 14: ...Model D1976 DW 955 Date 2000 06 Page 14 DOOR 1 2 3 4 5 6 7 8 9 15 13 11 12 10 17 16 14 ...
Page 20: ...Model D1976 DW 955 Date 2000 06 Page 20 INTERIOR LIGHT 1 2 3 4 5 6 7 8 9 10 ...
Page 22: ......
Page 23: ......